TerminalUP this clamps pair is not used
+
+
+
+
+
+
+
+
+
AO UT AI N DOUT DIN UP
11 1 1
00 0 0
Fig. 3.6: Description of analog and digital inputs and outputs
3.4.2. Parameters
Tab.3.5: Table of digital and analog input and output parameters
passive
2× optically separated
digital output
bipolar SSR switch design
voltage for supplying load max. 30 V DC, 24 V AC
switched current typically 300 mA
resistance in on state max. 1 Ω
protection against current overload in on state
protection against overvoltage in off state
passive
2× optically separated
digital input
passive optical element design
input voltage 0–2,3 V will be evaluated as log. 0
input voltage 2–30 V will be evaluated as log. 1
max. value of input voltage 30 V
active
2× optically separated
analog output
current source 4–20 mA
load resistance max. 250 Ω
settings accuracy better than 0.1 %
passive
2× optically separated
analog input
sensitivity 0–20 mA (or after sw configuration 4–20 mA)
accuracy of measured values better than 0.1 %
input resistance 60 Ω
no protection against current overload
max. value of input current 50 mA
Analog inputs 0 and 1 have connected terminals -(minus), which are galvanically separated from the
modem GND.
13© RACOM s.r.o.– Wideband modems – PROFI MX160
Connectors