To Clean Clogged Power Nozzle

To Clean Clogged Power Nozzle

WARNING: Unplug cord from electrical outlet before servicing.

STEP 1: Remove Power Nozzle Assembly

Lay cleaner on flat surface with bottom side of nozzle (brush side) facing you then:

A)Remove swivel clamp screws and clamp.

B)Remove the two screws at the outer rear corners of the nozzle base plate only.

C)Lift unit body inlet section out of power nozzle base.

CLAMP SCREWS

SCREWS

STEP 2: Inspect

Inspect nozzle and cleaner inlet for clogs and debris.

INLET STEP 2: InspectINLET

STEP 3: Replace Power Nozzle Assembly

After cleaning, replace unit body inlet section into power nozzle base. Line up tabs in front of base plate with slots in nozzle cover. Press down on front while rocking base back into place. Be sure front tabs are in lock position.

Replace screws at rear corners. Reattach swivel clamp to nozzle base.