Oregon Scientific specifications User Manual, Modèle EMR801 Manuel de l’utilisateur

Models: EMR801

1 2
Download 2 pages 56.83 Kb
Page 1
Image 1
USER MANUAL

Wireless Indoor and Outdoor Thermometer with Digital Clock Model: EMR801

USER MANUAL

EN

OVERVIEW

FRONT VIEW

Thermomètre extérieur et intérieurModèle : EMR8011

9

 

8

2

 

7Manual backgroundManual backgroundManual backgroundManual background3

Manual background4

6Manual backgroundManual background5

1.Solar panel

2.Outdoor temperature

3.Indoor temperature / Time

4.Ice alert indicator

5.: Increase value ; auto-toggle of indoor temperature and time

6.MODE: Enter setting mode; toggle between indoor temperature and time

7.Main unit low battery indicator

8.Remote sensor low battery indicator

9.Remote sensor reception indicator

BACK VIEW

1

Manual backgroundManual backgroundManual background2

6Manual backgroundManual backgroundManual backgroundManual background 3

5Manual backgroundManual background4

1.Wall-mount hole

2.Mounting magnet

3.°C/°F: Select temperature unit

4.Battery compartment

5.Table stand

6.RESET: Reset unit to default settings

REMOTE SENSOR

2

1

4

3Manual backgroundManual backgroundManual background 5

1.LED status indicator

2.Wall mount hole

3.Battery compartment

4.RESET hole

5.CHANNEL switch

GETTING STARTED

SOLAR PANEL

The solar panel is an energy saving feature, which is an environmentally friendly way to provide additional power to the main unit and prolongs battery life. However, it cannot replace battery power entirely.

INSERT BATTERIES

1.Remove the battery compartment.

2.Insert the batteries, matching the polarities.

3.Press RESET after each battery change.

LOCATION

MEANING

 

 

Indoor temperature / time

Main unit batteries low

area

 

 

 

Outdoor temperature area

Sensor batteries low

 

 

SET CLOCK

1.Press and hold MODE for 2 seconds.

2.Press Manual background to change values.

3.Press MODE to confirm.

4.The settings order is: 12/24 hour format, hour and minute.

REMOTE SENSOR

To set up the sensor:

1.Open the battery compartment and insert the battery, matching the polarity.

2.Press RESET.

3.Close the battery door.

4.Place the sensor within 30 m (98 ft) of the main unit using the table stand , mounting magnet or wall mount.

TIP Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 1.5 m (5 ft) and which can shield it from direct sunlight or wet conditions for an accurate reading.

1.5 m (5 ft)

NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing.

SENSOR DATA TRANSMISSION

To search for a sensor:

Press and hold MODE + Manual background for 2 seconds.

The sensor reception icon in the remote sensor area shows the status:

ICON

 

DESCRIPTION

 

 

 

OUT

OUT

Main unit is searching

 

 

for sensor(s).

 

 

 

OUT OUT

OUT OUT

A channel has been

 

 

found.

 

 

 

OUT

 

The sensor cannot be

 

found.

 

 

 

 

 

TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results.

TIME AND INDOOR TEMPERATURE DISPLAY

To enable auto-toggle display of time and indoor temperature:

Press and hold for 2 seconds.

To disable auto-toggle display of time and indoor temperature:

Press MODE.

To manually toggle between time and indoor temperature display:

Press MODE.

ICE WARNING

If the sensor falls between 3°C to -2 °C (37°F to 28°F), the green LED indicator will flash, and will stop flashing once the temperature is out of this range.

NOTE As ice alert is only applicable to channel 1, to prevent flashing of LED, select channel 2 or 3 on outdoor sensor.

RESET

Press RESET to return to the default settings.

PRECAUTIONS

Do not subject the unit to excessive force, shock, dust, temperature or humidity.

Do not cover the ventilation holes with any items such as newspapers, curtains etc.

Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.

Do not clean the unit with abrasive or corrosive materials.

Do not tamper with the unit’s internal components. This invalidates the warranty.

Only use fresh batteries. Do not mix new and old batteries.

Images shown in this manual may differ from the actual display.

When disposing of this product, ensure it is collected separately for special treatment.

Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer’s care instructions for information.

The contents of this manual may not be reproduced without the permission of the manufacturer.

Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use.

NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice.

NOTE Features and accessories will not be available in all countries. For more information, please contact your local retailer.

SPECIFICATIONS

TYPE

DESCRIPTION

 

 

MAIN UNIT

 

 

 

L x W x H

68 x 24 x 96 mm

 

(2.68 x 0.94 x 3.78 in)

 

 

Weight

80 g (2.82 oz) without battery

 

 

Temperature range

-5°C to 50°C (23°F to 122°F)

 

 

Signal frequency

433 MHz

 

 

Power

2 x UM-4 (AAA)

 

1.5 V batteries

 

 

REMOTE UNIT (THN132N)

 

 

L x W x H

96 x 50 x 22 mm

 

(3.78 x 1.97 x 0.87 in)

 

 

Weight

62 g (2.22 ounces)

 

 

Transmission range

30 m (98 ft) unobstructed

 

 

Temperature range

-20°C to 60°C (-4°F to 140°F)

 

 

Power

1 x UM-3 (AA) 1.5 V batteries

 

 

ABOUT OREGON SCIENTIFIC

Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. If you’re in the US and would like to contact our Customer Care department directly, please visit: www2.oregonscientific.com/service/ support

For international inquiries, please visit:

www2.oregonscientific.com/about/international

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio / TV technician for help.

DECLARATION OF CONFORMITY

The following information is not to be used as contact for support or sales. Please visit our website at www2. oregonscientific.com/service for all enquiries.

We

 

Name:

Oregon Scientific, Inc.

Address:

19861 SW 95th Ave.,Tualatin,

 

Oregon 97062 USA

Telephone No.:

1-800-853-8883

declare that the product

Product No.:

EMR801

Product Name:

Wireless Indoor and Outdoor

 

Thermometer with Digital Clock

Manufacturer:

IDT Technology Limited

Address:

Block C, 9/F, Kaiser Estate,

 

Phase 1,41 Man Yue St.,

 

Hung Hom, Kowloon,

 

Hong Kong

is in conformity with Part 15 of the FCC Rules.Operation is subject to the following two conditions: 1) This device may not cause harmful interference.2) This device must accept any interference received, including interference that may cause undesired operation.

Thermomètre extérieur et intérieur

sans fil à horloge numérique

Modèle : EMR801

Manuel de l’utilisateur

FR

VUE D’ENSEMBLE

FACE AVANT

Manual background1

9

 

8

2

 

7Manual backgroundManual backgroundManual backgroundManual background3

Manual background4

6Manual backgroundManual backgroundManual background5

1.Panneau solaire

2.Température extérieure

3.Température intérieure / heure

4.Indicateur d’alerte du niveau de gel

5.: Augmente la valeur, alternance automatique de l’heure et de la température intérieure

6.MODE : Permet d’entrer dans le mode Réglages, d’alterner entre l’heure et la température intérieure

7.Indicateur de faiblesse des piles de l’appareil principal

8.Indicateur de faiblesse de la pile de la sonde sans fil

9.Indicateur de réception de la sonde sans fil

FACE ARRIERE

Manual backgroundManual background 1

Manual backgroundManual backgroundManual background2

6Manual backgroundManual backgroundManual backgroundManual background 3

5Manual backgroundManual background4

1.Trou de fixation murale

2.Aimant de montage

3.°C / °F : Permet de sélectionner l’unité de mesure de la température

4.Compartiment des piles

5.Support de table

6.RESET (REINITIALISER) : Réinitialise l’appareil aux réglages par défaut

SONDE SANS FIL

2

1

4

3Manual backgroundManual backgroundManual background 5

1.Indicateur de statut LED

2.Trou de fixation murale

3.Compartiment des piles

4.Fente RESET (Réinitialiser)

5.Bouton CHANNEL (CANAL)

Page 1
Image 1
Oregon Scientific EMR801 specifications User Manual, Thermomètre extérieur et intérieur sans fil à horloge numérique