Water Thermo Sensor

Model: THWR800 / THWR800A

USER MANUAL

EN

FRONT VIEW

1

1.LED indicator

BACK VIEW

1.Tubular casing

2.RESET button

3.String hole

SCREEN DISPLAY

1

2

3

1.Channel indicator

2.Low battery indicator

3.Temperature display

INTRODUCTION

This sensor is compatible with various weather station products that carry this logo .

GETTING STARTED

The battery compartment resides in the tubular casing, and the switches for selecting channels and temperature unit are located on the inside of the main lid.

1.Twist the main lid to (unlock position), then pull it apart from the tubular casing.

2.Remove the battery compartment lid and insert 2 x UM-3 / AA 1.5V batteries, matching the polarity. Replace the battery compartment lid.

2

3

1

4

NOTE Standard Alkaline batteries contain a significant amount of water. Because of this they will freeze in low temperatures of approximately -12°C (10°F). Disposable Lithium batteries have a much lower threshold for

THWR800A_M_R0.indd 1

temperature with an estimated freezing range of below -40°C (-40°F).

IMPORTANT Do not use rechargeable batteries.

WARNING While you may use Lithium batteries to power the sensor, and although the sensor can withstand low temperatures, it is not recommended to use it in temperatures below 0°C (32°F). Placing the sensor in frozen water may damage the unit.

3.The diagram below is the inside of the main lid. Select a channel from Channel switch (1). If using more than one remote unit, select a different channel number for each unit. Select the temperature unit from °C / °F switch (2).

1

2

4.Place the main lid back on the tubular casing and twist it to(lock position).

1

2

5.Press RESET.

USING THE SENSOR

1.The sensor has a string to loop through the hole at the base of the tubular casing. This can allow you to hang the unit while you immerse it in water.

2.Place the sensor in the water and make sure that it is within the effective transmission range (328 feet / 100 metres) from the main unit.

TIP Press RESET whenever the sensor is not performing as expected (e.g. unable to establish radio frequency link with the main unit).

TIP Place the sensor as closely as possible to the main unit. Otherwise, minimise obstructions such as doors, walls and furniture between the main unit and sensor if the sensor cannot be placed close to the main unit. You may need to experiment with various locations to get the best results.

NOTE With adequate power, the Liquid Crystal Display in outdoor temperatures will remain operational up to -28°C (-20°F).

NOTE Wireless ranges can be impacted by a variety of factors such as extremely cold temperatures. Extreme

cold may temporarily reduce the effective range between the sensor and the main unit. If the unit’s performance fails due to low temperature, the unit will resume proper functioning as the temperature rises to within the normal temperature range. No permanent damage will occur to the unit due to low temperatures.

BATTERY REPLACEMENT

Replace the batteries whenever the low battery icon shows on the remote sensor, or on the remote sensor area of the main unit. Press RESET after every battery replacement.

PRECAUTIONS

Do not subject the unit to excessive force, shock, dust, temperature or humidity.

Do not cover the ventilation holes with any items such as newspapers, curtains etc.

Do not clean the unit with abrasive or corrosive materials.

Do not tamper with the unit’s internal components. This invalidates the warranty.

Only use fresh batteries. Do not mix new and old batteries.

Images shown in this manual may differ from the actual display.

When disposing of this product, ensure it is collected separately for special treatment and not as normal household waste.

Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer's care instructions for information.

The contents of this manual may not be reproduced without the permission of the manufacturer.

Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use.

NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice.

SPECIFICATIONS

TYPE

DESCRIPTION

Dimension

100 mm (D) x 180 mm (H)

Weight

174 g

Operating range in

0°C (32°F) to 50°C (122°F)

water

 

Operating range in

-30°C (-22°F) to 85°C (185°F)

room temperature

 

Temperature

0.1°C (0.2°F)

resolution

 

Number of channels

3

 

- Channel 1:

 

approximately every 53 seconds

Data transfer

- Channel 2:

approximately every 59 seconds

 

 

- Channel 3:

 

approximately every 61 seconds

 

 

Transmission range

328 ft (100 m)

Transmission

433 MHz

frequency

 

Batteries

2 x UM-3 / AA 1.5V

 

 

Remote sensor

Up to 1 m (3.28 ft)

waterproof

 

ABOUT OREGON SCIENTIFIC

Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. If you’re in the US and would like to contact our Customer Care department directly, please visit:

www2.oregonscientific.com/service/support

OR

Call 1-800-853-8883.

For international inquiries, please visit: www2. oregonscientific.com/about/international

EU-DECLARATION OF CONFORMITY

Hereby, Oregon Scientific, declares that this Water Thermo Sensor (model: THWR800 / THWR800A) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service.

COUNTRIES RTTE APPROVED COMPLIED

All EU countries, Switzerland CH and Norway N

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio / TV technician for help.

DECLARATION OF CONFORMITY

The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientific.com, or on the warranty card for this product) for all inquiries instead.

We

 

Name:

Oregon Scientific, Inc.

Address:

19861 SW 95th Ave.,Tualatin,

 

Oregon 97062 USA

Telephone No.:

1-800-853-8883

declare that the product

Product No.:

THWR800 / THWR800A

Product Name:

Water Thermo Sensor

Manufacturer:

IDT Technology Limited

Address:

Block C, 9/F, Kaiser Estate,

 

Phase 1, 41 Man Yue St., Hung

 

Hom, Kowloon, Hong Kong

is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.

Sonde-Thermomètre d’Eau

Modèle : THWR800 / THWR800A

MANUEL DE L’UTILISATEUR

FR

FACE AVANT

1

1.Indicateur LED

FACE ARRIERE

1.Habitable tubulaire

2.Bouton RESET (Réinitialiser)

3.Fente pour lanière

AFFICHAGE

1

2

3

1.Indicateur de canal

2.Indicateur de faiblesse des piles

3.Affichage de la température

INTRODUCTION

Ce capteur est compatible avec les appareils de prévisions

météorologiques portant ce logo .

AU COMMENCEMENT

Vous trouverez le compartiment des piles à l’intérieur de l’habitacle tubulaire et les interrupteurs de sélection des canaux et de l’unité de température à l’intérieur du couvercle principal.

1.Positionnez le couvercle principal sur (position de déverrouillage) puis retirez-le de l’habitacle tubulaire.

2.Retirez le couvercle du compartiment des piles et insérez 2 piles UM-3 / AA 1,5 V en respectant les polarités. Remettez le couvercle du compartiment en place.

2

3

1

4

REMARQUE Les piles alcalines standard sont composées d’un volume d’eau non négligeable. Par conséquent, elles peuvent geler lors de températures inférieures à -12°C (10°F). Les piles aux lithium ont un seuil inférieur lors de températures froides, elle ne peuvent en effet geler qu’à -40°C (-40°F).

IMPORTANT Ne pas utiliser de piles rechargeables.

ATTENTION Même si vous utilisez des piles au lithium pour alimenter le capteur, et bien que le capteur puisse supporter de faibles températures, il n’est pas recommandé

3/20/08 5:06:18 PM

Page 1
Image 1
Oregon Scientific THWR800 user manual Front View, Back View, Screen Display, Introduction, Getting Started, Precautions

THWR800A, THWR800 specifications

The Oregon Scientific THWR800 and THWR800A are sophisticated wireless thermo-hygrometers that provide precise readings of temperature and humidity, making them an excellent choice for both home and professional use. These devices are designed to monitor indoor and outdoor environments, giving users essential information to maintain optimal conditions for comfort, health, or specific activities like gardening.

One of the key features of the THWR800 and THWR800A is their dual-channel capability, which allows users to monitor two different locations simultaneously. The thermo-hygrometers come with an external sensor that can be placed outdoors to provide accurate outdoor temperature and humidity readings, while the internal sensor monitors the indoor conditions. This feature is particularly useful for homeowners looking to ensure a balanced environment, as well as for enthusiasts who are keen on maintaining specific climatic conditions for plants or delicate materials.

The sensors in both models leverage advanced wireless technology that ensures reliable transmission of data over a considerable distance, typically up to 300 feet (about 100 meters) in clear conditions. This wireless functionality allows for greater flexibility in sensor placement, enabling users to position the external sensor in the best location to capture accurate readings.

Both the THWR800 and THWR800A are equipped with an easy-to-read LCD display, showing real-time data on temperature and humidity. The display typically features symbols for optimal conditions, making it user-friendly and simple to interpret the information at a glance. Additionally, these devices often include features like minimum and maximum memory, which records the highest and lowest readings for temperature and humidity over a specified period. Such functionality helps users track fluctuations and maintain a stable environment.

The design of the Oregon Scientific THWR800 and THWR800A is compact and sleek, making them fit seamlessly into home or office decor. The battery operation ensures portability, and users can easily mount the external sensor on walls or set it on a flat surface.

In summary, the Oregon Scientific THWR800 and THWR800A are excellent options for anyone needing reliable monitoring solutions for temperature and humidity. With their wireless capabilities, dual-channel functionality, easy-to-read displays, and memory features, these devices stand out as practical tools for maintaining optimal environmental conditions. Whether for personal use, gardening, or professional settings, these thermo-hygrometers provide the precision and usability that consumers appreciate.