Memory | Current, Min and Max |
Alarm | Hi / Lo |
RADIO-CONTROLLED / ATOMIC CLOCK
Synchronization | Auto or disabled |
Clock display | HH:MM:SS |
Hour format | 12hr AM/PM or 24hr |
Calendar | DD/MM or MM/DD |
Weekday in 5 languages | (E, G, F, I, S) |
Battery | 4 x |
| AC adapter 6V |
REMOTE WIND SENSOR UNIT
Dimensions (L x W x H) | 178 x 76 x 214 mm (7 x 3 x 8.4 inches) |
Weight | 100 g (3.53 oz) without battery |
Wind speed unit | m/s, kph, mph, knots |
Speed accuracy | 2 m/s ~ 10 m/s (+/- 3 m/s) |
| 10 m/s ~ 56 m/s (+/- 10%) |
Direction accuracy | 16 positions |
Transmission of | Approx. every 14 seconds |
wind speed signal |
|
Memory | Max speed gust |
Battery | 2 x |
OUTDOOR TEMPERATURE / HUMIDITY UNIT
•RELATIVE TEMPERATURE
Dimensions | 115 x 87 x 118 mm |
(L x W x H) | (4.5 x 3.4 x 4.6 inches) |
Weight | 130 g (4.59 oz) without battery |
Temp. unit | °C / °F |
Displayed range | |
Operating range | |
Accuracy | |
| 0°C - 40°C: +/- 1°C (+/- 2.0°F) |
| 40°C - 50°C: +/- 2°C (+/- 4.0°F) |
| 50°C - 60°C: +/- 3°C (+/- 6.0°F) |
Comfort | 20°C to 25°C (68°F to 77°F) |
Memory | Current, Min and Max temp. |
| Dew Point w/ Max and Min |
| Wind chill temp. and min |
•RELATIVE HUMIDITY
Displayed range | 2% to 98% |
Operating range | 25% to 90% |
Resolution | 1% |
Accuracy | 25% - 40%: +/- 7% |
| 40% - 80%: +/- 5% |
| 80% - 90%: +/- 7% |
Comfort | 40% to 70% |
Memory | Current, Min and Max |
Battery | 2 x |
RF TRANSMISSION
RF frequency | 433MHz |
Range | Up to 100 meters (328 feet) with |
| no obstructions |
Transmission | Approx. every 60 seconds |
No. of Channel | 1 for Wind/ Rain/ UV and 10 for |
| Temp. / Humidity |
REMOTE RAIN GAUGE
Dimensions | 114 x 114 x 145 mm |
(L x W x H) | (4.5 x 4.5 x 5.7 inches) |
Weight | 241g (8.50 oz) without battery |
Rainfall unit | mm/hr and in/hr |
Range | 0 mm/hr – 9999 mm/hr |
Resolution | 1 mm/hr |
Accuracy | < 15 mm/hr: +/- 1 mm |
| 15 mm to 9999 mm: +/- 7% |
Memory | Past 24hrs, hourly and accumulated |
| from last memory reset |
Battery | 2 x |
ABOUT OREGON SCIENTIFIC |
Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. If you’re in the US and would like to contact our Customer Care department directly, please visit: www2.oregonscientific.com/service/support.asp
For international inquiries, please visit: www2.oregonscientific.com/about/ international.asp
EN
EU-DECLARATION OF CONFORMITY
Hereby, Oregon Scientific, declares that this Professional Weather Center (Models: WMR200 / WMR200A) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service.
COUNTRIES RTTE APPROVAL COMPLIED
All EU countries, Switzerland | CH |
and Norway | N |
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio / TV technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for support or sales. Please visit our website at www2.oregonscientific.com/service for all enquiries.
We |
|
Name: | Oregon Scientific, Inc. |
Address: | 19861 SW 95th Ave.,Tualatin, |
| Oregon 97062 USA |
Telephone No.: | |
declare that the product |
|
Product No.: | WMR200 / WMR200A |
Product Name: | Professional Weather Center |
Manufacturer: | IDT Technology Limited |
Address: | Block C, 9/F, Kaiser Estate, |
| Phase 1,41 Man Yue St., |
| Hung Hom, Kowloon, |
| Hong Kong |
is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.
11