SPECIFICATIONS
Model # | |
GENERAL |
|
Power Source | 12VDC (Operating Voltage: |
Power Consumption | Approximately 14W |
Operating Temperature | +41˚F to 104˚F (+5˚C to +40˚C) |
Operating Humidity | 35% ~ 80% |
Weight | Approximately 11 lbs. |
Dimensions (H x W x D) | 43⁄4" x 105⁄8" x 139⁄16" |
SYSTEM |
|
Television System | EIA standard, NTSC color signal; 525 lines, 60 fields |
Video Recording System | 2 rotary heads, helical scanning system (VHS mode) |
Video Head System | 4 rotary heads |
Modulation System | Luminance; FM azimuth recording chrominance; |
| Converted subcarrier phase shift recording |
Audio Track | 1 track |
TAPE TRANSPORT |
|
Tape Format | VHS tape |
Tape Speed | |
Recording Time | |
| |
FF/Rewind Time | Approximately 3 min. |
VIDEO |
|
Video In (BNC) | 1.0V |
Video Out (BNC) | 1.0V |
Horizontal Resolution | VHS |
AUDIO |
|
Audio In (Phono) | |
Mic In (M3) | |
Audio Out (Phono) | |
Audio Frequency Response | 50Hz ~ 10kHz |
CONNECTORS |
|
Terminal Input | Alarm, alarm reset, summer time |
Terminal Output | Tape end, warning |
Camera Switching Signal | 12V/0V, pulse width: 16.67ms |
Remote Control | For |
Weight and dimensions shown are approximate. Specifications subject to change without notice.
This product may be subject to export control regulations.
Warning: Unauthorized recording of copyrighted television programs, films, videotapes and other materials may infringe upon the right of copyright owners and be contrary to copyright laws.
1.Audio input/output connectors (phono jacks)
2.Vertical hold controls (2h, 6h) When the image on the TV monitor runs vertically during
3.Video input/output connectors Video input/output connectors (BNC); connect the input connector to the video camera, etc. and the output connector to the TV monitor, etc.
4.Camera switching output connector Camera switching output connector; connect it to the sequential switcher.
5.Battery installation area Install the battery in this area.
6.Alarm input connector
Alarm recording input connector; connect it to the external sensor.
7.COMMON terminal
8.Alarm reset connector
Input connector for releasing alarm recording; +4 to +12VDC voltage is required.
9.SUMMER TIME connector
This is used to switch between the present time and summer time.
10.Tape end output connector
When the cassette tape comes to its end during recording, the alarm device installed externally is activated.
11.WARNING output connector
When trouble has occurred in the unit, the alarm device installed externally is activated.
12.Ground terminal
13.12VDC input connector (Caution) When being powered by the car battery, wire the +12V power line using a 5A fuse.
DIMENSIONS