TNT Physical Specifications

Mineral tank sizes shown are with composit/FRP tanks.

 

 

 

RECOMMENDED BRINE TANK

MINERAL TANK

APPROXIMATE

 

PIPE SIZE

MINERAL TANK

SIZE

SALT STORAGE

GRAVEL UNDERBEDDING

SHIPPING WEIGHT

MODEL

(INCHES)

(INCHES)

(INCHES)

( LBS)

1/4" X 1/8"

#20

SINGLE

TWIN

TNT-300-24

3

24 X 72

30 X 50

1,110

0

150

1085

2145

TNT-300-30

3

30 X 72

30 X 50

1,110

200

75

1160

2295

TNT-450-30

3

30 X 72

39 X 48

2,030

200

75

1600

3120

TNT-450-36

3

36 X 72

39 X 48

2030

300

150

1835

3590

TNT-600

3

36 X 72

39 X 48

1,640

300

150

2115

4135

TNT-750

3

42 X 72

42 X 60

2,580

500

175

3475

6325

TNT-900

3

42 X 72

50 X 60

4,130

500

175

4280

8560

TNT-1200

3

48 X 72

50 X 60

3,495

700

200

4800

8760

TNT Capacity Ratings

 

RESIN

 

 

RATED CAPACITY

 

FLOW RATES (gpm)

BKW

 

 

LOW SALT

MEDIUM SALT

HIGH SALT

 

 

MODEL

CU.FT.

GRAINS/LBS

GRAINS/LBS

GRAINS/LBS

15 PSI

25 PSI

GPM

TNT-300-24

10

 

190,000/60

280,000/100

320,000/150

120

170

12

TNT-300-30

10

 

190,000/60

280,000/100

320,000/150

175

225

20

TNT-450-30

15

 

285,000/90

420,000/150

480,000/225

158

212

20

TNT-450-36

15

 

285,000/90

420,000/150

480,000/225

200

278

30

TNT-600

20

 

380,000/120

560,000/200

640,000/300

189

257

30

TNT-750

25

 

475,000/150

700,000/250

800,000/375

212

280

40

TNT-900

30

 

570,000/180

840,000/300

960,000/450

215

282

50

TNT-1200

40

 

760,000/240

1,120,000/400

1,280,000/600

213

280

50

1. Steel tank design configurations available up through 60” tank diameters. Consult factory for details.

OPERATING CONDITIONS

1.Water Pressure 30 - 100 psi.

2.Water temperature is not to exceed 110°F and the unit cannot be subject to freezing conditions. Consult factory for higher water temperature applications.

3.Limit of 2 ppm of Ferrous Iron. Add 3 grains per gallon of hardness for each ppm of iron present.

4.Flex connectors and vacuum breakers are required when using the PolyGlass Composite mineral tanks.

5.Backwash flow rates are calculated at 4 gpm per sq. ft. of bed area and rounded off based on 50ºF water temperature.

TNT Series Fiberglass Dimensions

with Six-Inch Flange Opening

 

 

HEIGHT

INLET/OUTLET HEIGHTS

SUGG. WIDTH

MODEL

TOP MOUNT

SIDE MOUNT

TOP MOUNT

SIDE MOUNT

SINGLE

TWIN

HT*

 

HS**

IT

IS

 

 

TNT-300-24

101

 

87.5

82.5

51

62

99

TNT-300-30

101

 

87.5

80

51

68

108

TNT-450-30

112

 

96.5

80

51

83

117

TNT-450-36

112

 

97

81

51

83

129

TNT-600-36

112

 

97

81

51

83

129

TNT-750-42

113

 

104.5

92

51

92

144

TNT-900

113

 

104.5

92

51

92

144

TNT-1200-48

116

 

103

93

51

106

164

All dimensions ±1” and are subject to change without notice. Use as reference only. *Allow additional 12” for resin filling on HT dimension.

**Allow additional 18” for resin filling on HS dimension. Call factory for optional tank & dimensional configurations.

Product Improvement designs are subject to change without notice.

HELLENBRAND, INC.

1-800-626-1417

www.hellenbrand.com

DEALER NAME:

73-054 9/08-LBRY

Page 8
Image 8
Hellenbrand manual TNT Physical Specifications, TNT Capacity Ratings, TNT Series Fiberglass Dimensions

TNT Series specifications

The Hellenbrand TNT Series represents a significant advancement in water treatment technology, specifically designed to offer high-performance solutions for residential and commercial applications. Known for its innovative design and robust performance, the TNT Series combines advanced filtration techniques with user-friendly operation, catering to diverse water quality challenges.

One of the standout features of the TNT Series is its multi-stage filtration system. This system employs multiple processes to effectively remove impurities, contaminants, and undesirable minerals from water. Each stage is engineered to target specific types of pollutants, ensuring that the water meets strict quality standards. The result is crystal-clear water free from sediment, chlorine, heavy metals, and other harmful substances that can affect health and taste.

Another key characteristic of the TNT Series is its use of advanced technology for efficiency and ease of maintenance. The series includes smart control systems that allow users to monitor and manage water quality in real-time. These smart systems come equipped with diagnostic tools, providing alerts for necessary maintenance or component replacement, thus prolonging the system’s lifespan and ensuring optimal performance.

Energy efficiency is a priority in the design of the Hellenbrand TNT Series. The units are engineered to operate with minimal energy consumption, reducing overall utility costs for homeowners and businesses. Additionally, the design features a compact footprint, making it easy to install in various spaces without requiring significant modifications to existing plumbing systems.

The TNT Series also incorporates user-friendly features, such as a simple interface for adjusting settings and monitoring performance. This focus on usability ensures that even individuals without technical expertise can operate and maintain the system with ease.

Durability and reliability are hallmarks of the TNT Series. Constructed from high-quality materials, these systems are built to withstand the rigors of continuous use while maintaining optimal filtration effectiveness. Hellenbrand's commitment to quality ensures that customers receive long-lasting products that deliver consistent results.

In summary, the Hellenbrand TNT Series stands out in the market for its comprehensive filtration, advanced technology, energy efficiency, ease of use, and durability. This series is an excellent choice for those seeking reliable and effective water treatment solutions, making it a valuable investment for both residential and commercial installations. With the Hellenbrand TNT Series, users can enjoy peace of mind knowing their water quality is in expert hands.