Error Messages
When a problem has occurred in the unit, one of the following error codes and warning displays will be displayed on the status display window.
Error code | Warning display | Description | |
|
|
| |
|
| This appears when condensation (dew) has been detected. | |
— d — | HUMID | Even after the cancellation of condensation detection, “HUMID” continues to flash for 20 | |
|
| minutes and the unit does not respond to the control key in order to ensure safety. | |
|
|
| |
|
| This appears when the servo has failed to lock for more than 3 seconds. | |
E — 00 | SERVO | If “T&S&R” has been selected as the setup menu item No. 003 setting, “SERVO NOT | |
LOCKED” is displayed on the third line (amount of remaining tape line) of the monitor | |||
|
| ||
|
| screen. | |
|
|
| |
|
| This appears when there is no head output (due to clogging, etc.) for more than 3 | |
|
| seconds. | |
E — 01 | RF | “L” is displayed on the first line (counter line) of the monitor screen. | |
|
| If “T&S&R” has been selected as the setup menu item No. 003 setting, “LOW RF” is | |
|
| displayed on the third line (amount of remaining tape line) of the monitor screen. | |
|
|
| |
|
| This appears when the error rate has deteriorated (when the three channel condition | |
|
| segments have lighted up). | |
E — 02 | RF | If “T&S&R” has been selected as the setup menu item No. 003 setting, “HIGH ERROR | |
|
| RATE” is displayed on the third line (amount of remaining tape line) of the monitor | |
|
| screen. | |
|
|
| |
|
| This appears when a blank portion on the tape has been detected. | |
|
| “N” is displayed on the first line (counter line) of the monitor screen. | |
|
| If “T&S&R” has been selected as the setup menu item No. 003 setting, “NO RF” is | |
|
| displayed on the third line (amount of remaining tape line) of the monitor screen. | |
E — 09 | RF | When all the following conditions are satisfied, the part of the tape concerned is | |
|
| recognized as a blank part. | |
|
| OWhen there is no output from any of the heads | |
|
| OWhen no playback data can be read | |
|
| OWhen there is no CTL signal | |
|
|
| |
E — 11 | SLACK | This appears when the reel base, which operates in accordance with the size of the | |
tape, has locked up for more than 2.5 seconds. | |||
|
| ||
|
|
| |
|
| This appears when the cassette down operation fails to take place even when 4 | |
E — 21 | SLACK | seconds have elapsed after the cassette was inserted. | |
Alternatively, it appears when the cassette fails to be ejected even when 4 seconds | |||
|
| ||
|
| have elapsed after its ejection operation was performed. | |
|
|
| |
E — 31 | SLACK | This appears when the loading operation fails to be completed within 4 seconds. | |
|
|
| |
E — 32 | SLACK | This appears when the unloading operation fails to be completed within 4 seconds. | |
|
|
| |
E — 41 | SLACK | This appears when the FG signal (rotational speed signal) fails to be output from the | |
cylinder motor. | |||
|
| ||
|
|
| |
E — 42 | SLACK | This appears when the PG signal (phase signal) fails to be output from the cylinder | |
motor. | |||
|
| ||
|
|
| |
E — 43 | SLACK | This appears when the cylinder motor’s speed is abnormally high. | |
|
|
| |
E — 44 | SLACK | This appears when the cylinder motor’s speed is abnormally low. | |
|
|
| |
E — 51 | SLACK | This appears when the FG signal (rotational speed signal) fails to be output from the | |
capstan motor. | |||
|
| ||
|
|
| |
E — 52 | SLACK | This appears when the capstan motor’s speed is abnormally high. | |
|
|
| |
E — 53 | SLACK | This appears when the capstan motor’s speed is abnormally low. | |
|
|
| |
E — 61 | SLACK | This appears when the supply reel motor has locked up. | |
|
|
| |
E — 62 | SLACK | This appears when the | |
|
|
| |
E — 63 | SLACK | This appears when the supply reel motor’s speed is abnormally high. | |
|
|
| |
E — 64 | SLACK | This appears when the | |
|
|
|