Error messages
Displaying the “HOURS METER” information
Turn the search dial to move the cursor ( * ). The description for the item where the cursor is located is shown on the counter display.
Item No. | Item | Description |
|
|
|
H00 | OPERATION | Displays the time that the power has been supplied in |
|
|
|
H01 | DRUM RUN | Displays the time that the drum has been rotating in |
|
|
|
H02 | TAPE RUN | Displays the time that the tape has been running during FF, REW, PLAY, SEARCH (JOG, |
|
| VAR, SHTL), REC, and EDIT modes (except for STILL in the JOG, VAR or SHTL mode) in |
|
| |
|
|
|
H03 | THREADING | The number of times for threading/unthreading is displayed in single units. |
|
|
|
H11 | DRUM RUN r | Displays the time that the drum has been rotating in |
|
|
|
H12 | TAPE RUN r | Displays the time that the tape has been running during FF, REW, PLAY, SEARCH (JOG, |
|
| VAR, SHTL), REC, and EDIT modes (except for STILL in the JOG, VAR or SHTL mode) in |
|
| |
|
|
|
H13 | THREADING r | The number of times for threading/unthreading is displayed in single units. (Can be reset) |
|
|
|
H30 | POWER ON | The number of times the power has been turned on is displayed in single units. |
<Notes>
•The resettable items in the “HOURS METER” information are reset by the shop when performing maintenance or other work.
•The search buttons and the search dial cannot be operated while the DIAG menu is displayed.
If “T&S&M” is selected in the setup menu No. 006 (DISPLAY SEL), a message appears in the mode display whenever a warning or error occurs. When multiple events occur, the event with the highest priority is displayed.
Priority | Display | Description |
|
|
|
High | Error messages | When an abnormal operation is detected in this unit, the AUTO OFF lamp lights up |
| (See error message table) | and an error message is displayed. |
|
|
|
| INT SG | This appears at the commencement (of the EE mode) for 2 seconds if the REC |
|
| button or EDIT button is pressed while the setup menu item No.600 (INT SG) has |
|
| been selected. Similarly, it appears for 2 seconds at the commencement of editing. |
|
|
|
| NO INPUT | This appears at the commencement (of the EE mode) for 2 seconds if the REC |
|
| button or EDIT button is pressed when the quality of the |
|
| exception of analog audio |
|
| INPUT SELECT switch is poor. Similarly, it appears for 2 seconds at the |
|
| commencement of editing. |
|
|
|
| Warning messages | When a warning occurs in this unit, the warning lamp lights up and a warning |
| (See error message table) | message is displayed. When multiple warnings occur, the warning with the highest |
Low |
| priority is displayed. |
|
|
|
Warning messages
Priority | Monitor display | Description | VTR operation | |
|
|
|
| |
High | FAN STOP | This is displayed when the fan motor stops. | Operation continues | |
|
|
|
| |
| NO RF | This appears when a blank part of the tape lasting for 1 or more |
| |
|
| seconds has been detected during playback. |
| |
|
| When all the following conditions have been met, it will be recognized | Operation continues | |
|
| as a blank part. | ||
|
|
| ||
|
| · When no signals are output from any of the heads |
| |
|
| · When the playback data cannot be read |
| |
|
| · When CTL is not present |
| |
|
|
|
| |
| SERVO NOT | This is displayed when the servo is not locked for three or more | Operation continues | |
| LOCKED | seconds during playback, recording, or editing. | ||
|
| |||
|
|
|
| |
| LOW RF | This is displayed when envelope levels approximately 1/3 that of |
| |
|
| normal levels are detected for more than one second during | Operation continues | |
|
| playback, recording, or editing. |
| |
|
|
|
| |
| HIGH ERROR | This is displayed when the error rate increases and correction/ | Operation continues | |
Low | RATE | interpolation is performed on either the video or audio playback signal. | ||
| ||||
|
|
|
|
– 87 –