TC/CHR CONVERT menu

This menu is displayed by pressing the following keys: TC/CHR ) F9 When the center cursor key is pressed, the 24TC display is highlighted. To enter the time code, use the number keys and cursor keys (2, 1) to set the time code, and then press the ENT key. Move on to the 30TC/25TC value setting using the

cursor keys (3, 4), and proceed in the same way to set and enter the time code.

F13

F12

F11

F10

F9

 

F1

F2

F3

F4

F5

F6

F7

F8

Key

Key designation

 

 

 

Description

 

 

F1–F2

——

 

 

 

 

 

 

 

F3

SYNC PHASE°

For setting the reference for the 3:2 conversion sequence.

A:Frame A is used as the reference to convert the time code.

B:Frame B is used as the reference to convert the time code.

C:Frame C is used as the reference to convert the time code.

D:Frame D is used as the reference to convert the time code.

F4

——

 

F5

DF MD°

For selecting whether the 3:2 pull-down output from the 1080/23psf

 

 

(p) or 1080/24psf (p) format after it is converted into the time code

 

 

and output is to be in the drop frame or non-drop frame mode.

 

 

DF: The output will be in the drop frame mode.

 

 

NDF: The output will be in the non-drop frame mode.

 

 

 

F6–F7

——

 

F8

EXIT

Returns the VTR to the TC/CHR menu screen.

 

 

 

F9

——

 

 

 

 

F10

RC_TC°

For selecting the time code which is to be output to the remote

 

 

connectors (RS-422, etc.).

 

 

24TC: The original time code with the frame count of 24 is output.

 

 

30TC: The post-conversion time code with the frame count of 30

 

 

is output.

F11

SD SUPER

For selecting the time code which is to be output to the SD monitor connector.

 

 

24TC: The original time code with the frame count of 24 is output.

 

 

30TC/(25TC): The post-conversion time code with the frame

 

 

count of 30/(25) is output.

 

 

 

F12

HD SUPER

For selecting the time code which is to be output to the HD monitor

 

 

connector.

 

 

24TC: The original time code with the frame count of 24 is output.

 

 

30TC/(25TC): The post-conversion time code with the frame

 

 

count of 30/(25) is output.

 

 

 

F13

LTC OUT°

For selecting the time code which is to be output to the LTC output connector.

 

 

24TC: The original time code with the frame count of 24 is output.

 

 

30TC: The post-conversion time code with the frame count of 30

 

 

is output.

°This is not displayed with the 50i/25psf (p).