Panasonic AJ8 (J8) manual AJ8 J8, Features, Precautions When Using Cadmium-Free Contact Type

Models: AJ8 (J8)

1 6
Download 6 pages 48.42 Kb
Page 1
Image 1
AJ8 (J8)

AJ8 switch standard actuator

AJ8 (J8)

POWER ROCKER SWITCH

AJ8 (J8)

SWITCHES

 

 

 

FEATURES

AJ8 switch Wide actuator

RoHS Directive compatibility information

http://www.nais-e.com/

1.Power rocker switches for safety requirements.

• All versions comply with ClassII EN61058-1 insulation grade. Insulation distance: 8mm Min. Contact gap: 3mm Min.

• International Standard-approved status

 

 

Already approved

 

 

 

 

Standard

UL, CSA, VDE, TÜV,

 

ÖVE, KEMA, SEMKO,

 

actuator

 

NEMKO, DEMKO,

 

type

AJ8

FIMKO, SEV

 

switch

Wide

UL, CSA, VDE, TÜV,

 

SEMKO, NEMKO,

 

actuator

 

DEMKO, FIMKO, SEV,

 

type

 

KEMA, ÖVE

 

 

 

 

 

2. High inrush current resistance is ideal for office automation equipment.

Type

Inrush

Contact

Expected

rating

life

 

 

 

 

 

 

AJ8

160A

16A 250V AC

Min.104

 

 

 

 

3. Operation that only requires a light touch

The best operation characteristics were sought by analyzing touch data gathered by monitoring 1,500 people.

• Power Rocker Switch touch curve

4. A broad product line

The AJ8 switches are available with five different types of terminals:quick-connect terminals, soldering terminals, PC board terminals, right angle terminals and left angle terminals.

5.Eight standard actuator colors White, black, red, dark gray, light gray, blue, green, yellow

6.Cadmium-free contact compatibility.

PRECAUTIONS WHEN USING CADMIUM-FREE CONTACT TYPE

Models with cadmium-free contacts have been introduced in order to reduce environmentally harmful substances. (“F” is affixed to the end of the part number.) We ask customers who are currently using products with cadmium-containing contacts (no “F” at the end of the part number) to please make the switch to models with cadmium-free contacts. When switching, operating life may differ depending on the load. Please be sure to verify this by conducting an evaluation using actual equipment.

Stroke

CONSTRUCTION

Actuator

Case

Snap-in Clip POWER ROCKER SWITCH

SWITCHESFEATURES Contact gap (more than 3mm)

The EN60950 (intended for office automation equipment) conforms with a 3mm gap.

When directly opening or closing the primary power supply side, a contact gap of at least 3mm is required in order to ensure safety.

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.