Major operating controls and their functions

ENGLISH

Function Switches [SW1, SW2, SET UP] (Factory defaults: SW1 = OFF, SW2 = OFF, SET UP No.1 = ON, SET UP No.2 to 4 = OFF)

This is used to select the operations of the AW-IF400. Before changing a setting, the power must be turned off. SETUP No.3 is the tilt range selector switch which is used to control the AW-PH400 from the AW-RP605A.

At the ON position, the range is 300 degrees; at the OFF position, it is 190 degrees. For any other combination, use the switch at the OFF position.

DC 12 V input connector [DC12V IN]

Connect the AW-PS505A AC adapter (sold separately) to this socket.

Cable clamp

This is used to clamp the power cable in place and prevent it from coming loose.

 

SW1

SW2

 

 

SET UP

 

 

Functions

No.1

No.2

No.3

 

No.4

 

 

MODE SET

 

TILT RANGE

NOT USE

Controlling PH400 from RP605A

OFF

OFF

ON

OFF

ON

 

OFF

OFF

(300 deg)

(190 deg)

 

 

 

 

 

 

 

 

 

Extending communication distance

ON

ON

OFF

OFF

OFF

 

OFF

between RP400 and PH400

(Set at RP400)

 

 

 

 

 

Controlling PH350 from RP400

OFF

ON

OFF

ON

OFF

 

OFF

- 8 (E) -

Page 9
Image 9
Panasonic AW-IF400G manual  DC 12 V input connector DC12V,  Cable clamp