tAC 120V Inlet [AC IN](AC 3P Inlet) Connect the supplied AC cable.

FRONT PANEL

AC IN

 

 

LAMP AC OUT

OPTION SW OPTION SW

LAMP

DC 15V

CONTROL OUT CONTROL IN

CONTROL

OUT

OP

C S

+

100V 500W

tAC 120V Inlet [AC IN](AC 3P Inlet) Connect the supplied AC cable.

yOption Switch Terminal (OPTION SW CONTROL OUT) (2P Terminal Board)

A relay switch capable of controlling the contact to short or open from a Control Panel (AW-RP301, AW- RP305, AW-RP501, or AW-RP505). The terminal board has a maximum capacity of 120 V, 1 A (AC/DC), and is valid when it is connected to OPTION SW CONTROL IN Terminal u on the pan/tilt head.

uOption Switch Control Input Terminal (OPTION SW CONTROL IN) (1P Terminal Board)

Connect it to OP Output Terminal on the pan/tilt head when controlling OPTION SW CONTROL OUT Terminal

yto short or open, using a cable (to be locally pur- chased) with a nominal cross section of 0.3 mm2 or more that meets the UL specifications. The maximum allowable cable length is 30 meters.

Applicable Wire

Solid wire:

ø1.02 (AWG 18)

Stranded wire:

0.75 mm2

Usable wire range

 

 

Solid wire:

ø0.64 to ø1.02

 

(AWG 22 to 18)

Stranded wire:

0.3 mm2 to 0.75 mm2

 

(AWG 22 to 20)

 

Strand diameter: ø0.18 or more

Standard bare end length

10 mm