Panasonic AW-PS300 manual i Lamp Control Input Terminals LAMP CONTROL C/S 2P Terminal Board

Models: AW-PS300

1 11
Download 11 pages 27.56 Kb
Page 7
Image 7

iLamp Control Input Terminals (LAMP CONTROL C/S) (2P Terminal Board)

Connect it to LAMP CONTROL C/S Terminals on the pan/tilt head when controlling the halogen lamp con- nected to LAMP AC OUT Connector !0to switch it on and off, using a cable (to be locally purchased) with a nominal cross section of 0.3 mm2 or more that meets the UL specifications. The maximum allowable cable

length is 30 meters.

 

 

Applicable wire

 

 

Solid wire:

ø1.29 (AWG 16)

Stranded wire:

1.25 mm2 (AWG 16)

Usable wire range

 

 

Solid wire:

ø0.64 to ø1.29

 

(AWG 22 to 16)

Stranded wire:

0.3 mm2 to 1.25 mm2

 

(AWG 22 to 16)

 

Strand diameter ø0.18 or more

Standard bare end length

11 mm

oDC 15V Output Terminal (DC 15V OUT +/–)

(2P Terminal Board)

Connect it to (DC 15V IN +/– Terminals) on the pan/tilt head with a cable (to be locally purchased) with a nom- inal cross section of 1.25 mm2 or more that meets the UL specifications. The maximum allowable cable length is 30 meters.

Applicable (usable) wire

 

Solid wire:

ø1.29 (AWG 16)

Stranded wire:

1.25 mm2 (AWG 16)

 

Strand diameter ø0.18 or more

Standard bare end length

11 mm

!0Lamp AC Output Connector [LAMP AC OUT] (AC 3P Outlet)

AC Output Connector for halogen lamps to be switched on and off from a Control Panel (AW-RP301, AW-RP305, AW-RP501, or AW-RP505). Locally pur- chase an AC plug conversion cable that matches the AC plug for the halogen lamp to be used. Connect a halogen lamp of 250 W to 500 W. If a halogen lamp of less than 250 W is connected, the LAMP Indicator on the control panel may flash to indicate a burnt bulb even though the lamp is normal.