Setting the Fan Speed

Press 4 to select:-

FAN

 

 

 

 

 

Low Fan Speed

FAN

 

 

 

 

 

 

Medium Fan Speed

FAN

 

 

 

 

 

 

High Fan Speed

 

 

 

 

AUTO

 

 

 

 

 

FAN –

Automatic Fan Speed

 

 

 

 

 

The speed of the indoor fan is adjusted

 

 

 

 

 

automatically according to the operation.

 

 

 

 

 

The indoor fan stops occasionally during

 

 

 

 

 

cooling operation.

Setting the Vertical Airflow Direction

• Press 5 or 6 to select:-

Cooling Model

 

COOL / DRY Operation

 

FAN Operation

 

 

AUTO

 

 

 

AUTO

 

 

 

 

36°

 

 

61°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Swing up/down

 

Move up/down

 

 

Automatically

 

Automatically

 

 

 

 

 

 

 

 

 

 

 

 

 

MANUAL

 

 

 

MANUAL

 

 

 

 

 

 

Five stages of adjustment

 

 

Five stages of adjustment

 

 

 

can be made between

 

can be made between

 

 

14° ~ 36°.

 

0° ~ 61°.

 

 

 

 

 

 

 

 

 

Heat Pump Model

 

 

 

 

 

 

 

 

COOL / DRY Operation

 

HEAT Operation

 

 

AUTO

 

 

AUTO

 

 

 

 

 

 

 

 

 

– When the discharge air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature is low such

 

 

 

 

 

 

 

 

as at the start of heating

 

 

36°

 

 

 

operation, the air blows

 

 

 

 

 

at horizontal level. As

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the temperature rises,

 

 

Swing up/down

 

the hot air blows at a

 

 

 

downward direction.

 

 

Automatically

 

 

 

– To stop this operation,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

press MANUAL.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MANUAL

 

 

 

MANUAL

 

 

 

 

Five stages of adjustment

 

Five stages of adjustment

 

 

can be made between

 

can be made between

 

 

14° ~ 36°.

 

0° ~ 61°.

 

 

 

 

CS-A7CKP CU-A7CKP5 / CS-A9CKP CU-A9CKP5 / CS-A12CKP CU-A12CKP5

Setting the Horizontal Airflow Direction

 

Operation Details

 

 

 

 

 

COOL – Cooling Operation

 

 

 

 

 

• To set the room temperature at your preference

 

 

 

 

 

cooling comfort.

 

 

 

 

 

AUTO – Automatic Operation

 

 

 

 

 

• Sense indoor temperature to select the optimum

• Adjust it manually

 

 

 

 

mode.

 

 

 

 

• Temperature is not displayed on the remote control

 

 

 

 

 

Use this air conditioner under the following

during AUTO operation.

 

conditions:

 

 

 

 

DRY – Soft Dry Operation

 

 

 

 

 

 

 

 

 

 

• A very gentle Cooling Operation, prior to

Cooling Model

 

 

 

dehumidification. It does not lower the room

 

 

 

temperature.

 

 

 

 

 

 

 

 

Unit in °C

• During Soft Dry operation, the indoor fan operates at

DBT: Dry Bulb Temp

Indoor

Outdoor

Low fan speed.

 

WBT: Wet Bulb Temp

DBT

WBT DBT

WBT

HEAT – Heating Operation

 

Maximum Temperature

32

23

43

26

(for Heat Pump Model only)

• Heat is obtained from outdoor air to warm up the

 

 

 

 

 

Minimum Temperature

16

11

16

11

room. When the outdoor ambient air temperature

 

 

 

 

 

falls, the heating capacity of the unit might be

 

 

 

 

 

reduced.

Heat Pump Model

 

 

• Defrosting Operation

 

 

Depend on the outdoor temperature, the operation

 

 

 

 

 

 

 

 

Unit in °C

occasionally stops to melt the frost on the outdoor

 

Indoor

Outdoor

unit.

DBT: Dry Bulb Temp

 

 

 

 

 

 

WBT: Wet Bulb Temp

DBT

WBT

DBT

WBT

FAN – Air Circulation Operation

Maximum Temperature-Cooling

32

23

43

26

(for Cooling Model only)

• When the room temperature reaches the set

(Maximum Temperature-Heating)

(30)

(-)

(24)

(18)

temperature, operation commences at Low airflow

 

 

 

 

 

Minimum Temperature-Cooling

16

11

16

11

volume. It stops when the room temperature drops to

2°C below the set temperature.

(Minimum Temperature-Heating)

(16)

(-)

(-5) (-6)

(It is useful when using a heater).

 

 

 

 

 

Notes

If the unit is not going to be used for an extended period of time, turn off the main power supply. If it is left at the ON position, approximately 2.5 W of electricity will be used even if the indoor unit has been turned off with the remote control.

If operation is stopped, then restart immediately, the unit will resume operation only after 3 minutes.

8

 

 

OFF/ON

 

7

MODE

QUIET

POWERFUL

6

 

 

 

AIR SWING

 

AUTO

MANUAL

FAN SPEED

 

1

1

2

3

3

ON

 

SET

 

 

 

5

OFF

 

CANCEL

4

 

 

 

 

 

TIMER

 

2

SETTING THE TIMER

Ensure that the current time is correct before setting the timer. The timer cannot be set if the time display is flashing.

ON-TIMER Operation

To start the air conditioner operation automatically.

Press 1 to set the operation.

Press 2 to increase or decrease the time.

Then press 3.

To cancel this operation, press 4.

OFF-TIMER Operation

To stop the air conditioner operation automatically.

Press 5 to set the operation.

Press 2 to increase or decrease the time.

Then press 3.

To cancel this operation, press 4.

Timer Mode Operation Details

When the ON-Timer is set, operation will start before the actual set time. This is to enable the room temperature reaches the set temperature at the set time.

 

Cooling Model

 

 

 

Heat Pump Model

 

 

 

 

 

 

COOL,DRY, –>15 minutes

 

 

 

COOL,DRY, –>15 minutes

 

 

 

 

 

 

AUTO

in advance

 

 

 

in advance

 

 

 

 

 

 

 

HEAT, AUTO –>30 minutes

 

 

 

 

 

 

 

in advance

 

 

 

 

 

 

 

 

 

Once the ON/OFF Timer is set, operation will start/ stop at the set time everyday.

The current time is not displayed when the timers are set.

When both timers are used together, the TIMER mode indicator on the indoor unit remains lit even when the operation is stopped by the OFF-TIMER.

CONVENIENCE OPERATION

Powerful Mode Operation

To obtain the set temperature quickly.

Press 6.

Powerful mode indicator (orange) on the indoor unit will light up.

Powerful mode will operate for 15 minutes only.

• To cancel this operation, press once more.

Powerful Mode Operation Details

• The changes of the temperature and airflow volume are automatic.

• The remote control display remains unchanged.

• If operation mode button is pressed, powerful operation will be cancelled.

• During FAN – Air circulation operation, the powerful operation are not available.

(cooling model only)

Powerful Mode

Temperature

Airflow

Operation

 

volume

 

 

 

 

3°C lower

 

COOL / DRY

than set temp.

Super High

 

 

 

HEAT

3°C higher

 

(for Heat Pump

than set temp.

Automatic

model only)

 

 

Quiet Mode Operation

To provide quiet operation.

• Press 7.

Quiet mode indicator on the indoor unit will light up.

To cancel this operation, press once more.

Operation Details

Air flow sound will reduce during operation.

Ionizer Mode Operation Produce negative ion for fresh air.

Press 8.

Ion mode indicator on the indoor unit will light up.

• To cancel this operation, press once more.

Operation Details

• Air conditioner ON:

Provide negative ion during operation.

• Air conditioner OFF:

Provide negative ion with FAN operation.

• If blinking, press 8 twice.

If still blinking, please call service.

41

Page 3
Image 3
Panasonic CS-A9CKP, CU-A12CKP5, CU-A7CKP5, CU-A9CKP5, CS-A12CKP, CS-A7CKP manual Setting the Timer, Convenience Operation

CU-A12CKP5, CS-A12CKP, CS-A7CKP, CU-A9CKP5, CU-A7CKP5 specifications

The Panasonic CS-A9CKP, CU-A7CKP5, CU-A9CKP5, CS-A7CKP, and CS-A12CKP air conditioning units represent a sophisticated blend of technology and efficiency designed to cater to diverse cooling and heating needs in residential and commercial settings. These models underscore Panasonic’s commitment to innovation, energy efficiency, and user comfort.

At the heart of these air conditioning systems is the advanced inverter technology that helps achieve significant energy savings by adjusting the compressor speed according to the cooling or heating demand. This ensures a comfortable indoor temperature while reducing electricity consumption. Additionally, these models typically boast a high Energy Efficiency Ratio (EER) and Seasonal Energy Efficiency Ratio (SEER), making them environmentally friendly options.

The CS-A9CKP and CS-A12CKP are particularly noteworthy for their powerful cooling capabilities, ideal for larger rooms and spaces. They also feature a wide operating temperature range, allowing them to perform optimally even in extreme weather conditions. The CU-A7CKP5 and CU-A9CKP5 units are designed to work seamlessly with their corresponding indoor counterparts, ensuring balanced airflow and efficient temperature management.

Another exceptional feature across these units is the presence of a four-way airflow system. This technology allows for better distribution of cool or warm air throughout the room, preventing hot or cold spots and enhancing overall comfort. Additionally, many models come equipped with built-in filters that improve indoor air quality by trapping dust and allergens, ensuring a healthier living environment.

For user convenience, these models often include smart technology options, such as Wi-Fi connectivity for remote control via smartphone applications. This feature allows users to adjust settings, set timers, and monitor energy usage from anywhere, adding significant convenience.

Finally, the quiet operation of these air conditioning systems makes them suitable for residential use, especially in bedrooms or study areas. The combination of efficiency and innovation in the Panasonic CS-A9CKP, CU-A7CKP5, CU-A9CKP5, CS-A7CKP, and CS-A12CKP units not only enhances comfort but also promotes sustainability, making them a suitable investment for energy-conscious consumers. With their array of features, these models showcase Panasonic's leading role in the HVAC industry, promising reliability and performance for years to come.