■Setting the Fan Speed
•Press 4 to select:-
FAN | | | | | | – | Low Fan Speed |
FAN | | | | | | | – | Medium Fan Speed |
FAN | | | | | | | – | High Fan Speed |
| | | |
AUTO | | | | | |
FAN – | Automatic Fan Speed |
| | | | | The speed of the indoor fan is adjusted |
| | | | | automatically according to the operation. |
| | | | | The indoor fan stops occasionally during |
| | | | | cooling operation. |
■Setting the Vertical Airflow Direction
• Press 5 or 6 to select:-
Cooling Model
| COOL / DRY Operation | | FAN Operation | |
| AUTO | | | | AUTO | | | |
| 36° | | | 61° | | | | |
| | | | | | | | | |
| Swing up/down | | Move up/down | |
| Automatically | | Automatically | |
| | | | | | | | | | |
| MANUAL | | | | MANUAL | | | | |
| | Five stages of adjustment | |
| Five stages of adjustment | | |
| can be made between | | can be made between | |
| 14° ~ 36°. | | 0° ~ 61°. | | | | |
| | | | | Heat Pump Model | |
| | | | | |
| COOL / DRY Operation | | HEAT Operation | |
| AUTO | | | AUTO | | | |
| | | | | | – When the discharge air | |
| | | | | | |
| | | | | | | temperature is low such | |
| | | | | | | as at the start of heating | |
| 36° | | | | operation, the air blows | |
| | | | at horizontal level. As | |
| | | | | | | |
| | | | | | | the temperature rises, | |
| Swing up/down | | the hot air blows at a | |
| | downward direction. | |
| Automatically | | |
| – To stop this operation, | |
| | | | | | |
| | | | | | | press MANUAL. | |
| | | | | | | | | | | | |
| MANUAL | | | | MANUAL | | | |
| Five stages of adjustment | | Five stages of adjustment | |
| can be made between | | can be made between | |
| 14° ~ 36°. | | 0° ~ 61°. | | | | |
■Setting the Horizontal Airflow Direction
• Adjust it manually
●Use this air conditioner under the following conditions:
Cooling Model
Unit in °C
DBT: Dry Bulb Temp | Indoor | Outdoor |
WBT: Wet Bulb Temp | DBT | WBT | DBT | WBT |
|
| | | | |
Maximum Temperature | 32 | 23 | 43 | 26 |
Minimum Temperature | 16 | 11 | 16 | 11 |
| | | | |
Heat Pump Model
Unit in °C
DBT: Dry Bulb Temp | Indoor | Outdoor |
WBT: Wet Bulb Temp | DBT | WBT | DBT | WBT |
|
| | | | |
Maximum Temperature-Cooling | 32 | 23 | 43 | 26 |
(Maximum Temperature-Heating) | (30) | (-) | (24) | (18) |
| | | | |
Minimum Temperature-Cooling | 16 | 11 | 16 | 11 |
(Minimum Temperature-Heating) | (16) | (-) | (-5) | (-6) |
| | | | |
●Notes
•If the unit is not going to be used for an extended period of time, turn off the main power supply. If it is left at the ON position, approximately 2.5 W of electricity will be used even if the indoor unit has been turned off with the remote control.
•If operation is stopped, then restart immediately, the unit will resume operation only after 3 minutes.
●Operation Details
COOL – Cooling Operation
•To set the room temperature at your preference cooling comfort.
AUTO – Automatic Operation
•Sense indoor temperature to select the optimum mode.
•Temperature is not displayed on the remote control during AUTO operation.
DRY – Soft Dry Operation
•A very gentle Cooling Operation, prior to dehumidification. It does not lower the room temperature.
•During Soft Dry operation, the indoor fan operates at Low fan speed.
HEAT – Heating Operation (for Heat Pump Model only)
•Heat is obtained from outdoor air to warm up the room. When the outdoor ambient air temperature falls, the heating capacity of the unit might be reduced.
•Defrosting Operation
Depend on the outdoor temperature, the operation occasionally stops to melt the frost on the outdoor unit.
FAN – Air Circulation Operation
(for Cooling Model only)
•When the room temperature reaches the set temperature, operation commences at Low airflow volume. It stops when the room temperature drops to 2°C below the set temperature.
(It is useful when using a heater).
8 | | | OFF/ON | |
7 | MODE | QUIET | POWERFUL | 6 |
| | |
AIR SWING
| AUTO | MANUAL | FAN SPEED | |
1 | 1 | 2 | 3 | 3 |
ON | | SET |
| | |
5 | OFF | | CANCEL | 4 |
| | |
| | TIMER | | 2 |
SETTING THE TIMER
Ensure that the current time is correct before setting the timer. The timer cannot be set if the time display is flashing.
■ON-TIMER Operation
To start the air conditioner operation automatically.
•Press 1 to set the operation.
•Press 2 to increase or decrease the time.
•Then press 3.
•To cancel this operation, press 4.
■OFF-TIMER Operation
To stop the air conditioner operation automatically.
•Press 5 to set the operation.
•Press 2 to increase or decrease the time.
•Then press 3.
•To cancel this operation, press 4.
●Timer Mode Operation Details
•When the ON-Timer is set, operation will start before the actual set time. This is to enable the room temperature reaches the set temperature at the set time.
| Cooling Model | | | | Heat Pump Model | |
| | | |
| COOL,DRY, –>15 minutes | | | | COOL,DRY, –>15 minutes | |
| | | |
| AUTO | in advance | | | | in advance | |
| | | | | | HEAT, AUTO –>30 minutes | |
| | | | | | in advance | |
| | | | | | | |
•Once the ON/OFF Timer is set, operation will start/ stop at the set time everyday.
•The current time is not displayed when the timers are set.
•When both timers are used together, the TIMER mode indicator on the indoor unit remains lit even when the operation is stopped by the OFF-TIMER.
CONVENIENCE OPERATION
■Powerful Mode Operation
To obtain the set temperature quickly.
•Press 6.
∗Powerful mode indicator (orange) on the indoor unit will light up.
∗Powerful mode will operate for 15 minutes only.
• To cancel this operation, press once more.
●Powerful Mode Operation Details
• The changes of the temperature and airflow volume are automatic.
• The remote control display remains unchanged.
• If operation mode button is pressed, powerful operation will be cancelled.
• During FAN – Air circulation operation, the powerful operation are not available.
(cooling model only)
Powerful Mode | Temperature | Airflow |
Operation | | volume |
| | |
| 3°C lower | |
COOL / DRY | than set temp. | Super High |
| | |
HEAT | 3°C higher | |
(for Heat Pump | than set temp. | Automatic |
model only) | | |
■Quiet Mode Operation
To provide quiet operation.
• Press 7.
∗Quiet mode indicator on the indoor unit will light up.
•To cancel this operation, press once more.
●Operation Details
•Air flow sound will reduce during operation.
■Ionizer Mode Operation Produce negative ion for fresh air.
•Press 8.
∗ Ion mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.
●Operation Details
• Air conditioner ON:
Provide negative ion during operation.
• Air conditioner OFF:
Provide negative ion with FAN operation.
• If blinking, press 8 twice.
If still blinking, please call service.