Outdoor Unit CU-KS30NKUA

2-2-2. Outdoor Unit

P.C.Board
Circuit Fuse
Controls
Part No.
-
250V 25A
POW-CH3082-B2
Noise Filer P.C.B
Microprocessor
400V 3.15A
CR-C3082-F
Control P.C.B
-
-
HIC-CH3072R-C1
H.I.C.Board
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Pints (cc)
-
Micro F
VAC
External Finish Acrylic baked-on enamel finish
FV68S ... 2.98 (1,400)
-
-
Internal Controller
Yes
Aluminum Plate Fin / Copper Tube
2
21.2
Face Area ft2 (m2)8.05 (0.748)
Coil
Rows
Fins per inch
Heat Exchanger Coil
SIC-71FW-D8120-4A ... 1
Compressor Oil ... Amount
8
142
750
Ohm
DC Motor
Type
Compressor Model / Nominal Output
Compressor
Coil Resistance (Ambient Temp. 77 °F (25 °C)) Ohm
DC Twin Rotary (Hermetic)
C-9RVN273H0H / 2,250W
T - R :
T - S :
R - S :
0.169
0.169
0.169
CT (Peak current cut-off control)
Compressor Discharge Temp. Control
Operation cut-off control in abnormal ambient Temp.
Safety Device
Micro F
VAC
Run Capacitor
Crankcase Heater
Yes
Yes
Yes
Overload Relay CS-7L110
Model
Operation Temp. Open : 230 °F (110 °C), Close : 203 °F (95 °C)
-
-
230V 30W
1 ... D19-9/32 (D490)
Fan
Propeller
Q'ty ... Dia. inch (mm)
Type
Type
Over- Heat Protection
(Ambient Temp. 68 °F (20 °C))
Fan Motor
Nominal Output
Coil Resistance
Safety Device
Rough Measure RPM (Cool)
Run Capacitor
Type
Model ... Q'ty
No. of Poles
W
Yes
Over- Current Protection
13