Outdoor Unit : CU-KS36NKUA

Indoor Unit : CS-KS36NKU

Power supply : 230V Single Phase 60Hz

RATING CAPACITY: 34,000 BTU/h AIR FLOW RATE: 630 CFM
INDOOR OUTDOOR
ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC)
WB DB 65 75 85 95 105 115
(18.3) (23.9) (29.4) (35.0) (40.6) (46.1)
TC 27,450 28,140 28,840 29,040 24,650 16,770
CI 2.61 3.02 3.43 3.67 3.22 2.48
72 (22.2) SHC 19,680 20,050 20,410 20,530 18,210 14,420
59 76 (24.4) SHC 22,000 22,370 22,740 22,860 20,530 16,740
(15.0) 80 (26.7) SHC 24,450 24,820 25,180 25,300 22,980 16,770
84 (28.9) SHC 26,770 27,140 27,510 27,630 24,650 16,770
88 (31.1) SHC 27,450 28,140 28,840 29,040 24,650 16,770
TC 35,010 34,360 33,600 33,100 24,850 16,910
CI 2.68 3.10 3.53 3.76 3.22 2.48
72 (22.2) SHC 20,170 19,800 19,310 19,070 15,030 11,480
63 76 (24.4) SHC 22,490 22,120 21,760 21,390 17,360 13,810
(17.2) 80 (26.7) SHC 24,940 24,570 24,200 23,840 19,800 16,250
84 (28.9) SHC 27,260 26,890 26,530 26,280 22,120 16,910
88 (31.1) SHC 29,580 29,220 28,850 28,610 24,450 16,910
TC 35,720 35,120 34,400 # 34,000 24,930 16,970
CI 2.77 3.20 3.64 3.85 3.22 2.48
72 (22.2) SHC 16,620 16,380 16,010 15,890 11,730 8,670
67 76 (24.4) SHC 19,070 18,700 18,330 18,210 14,180 11,000
(19.4) 80 (26.7) SHC 21,510 21,150 20,900 20,660 16,620 13,440
84 (28.9) SHC 23,840 23,590 23,230 22,980 18,940 15,770
88 (31.1) SHC 26,160 25,920 25,550 25,300 21,270 16,970
TC 36,270 35,710 35,040 34,780 24,870 16,950
CI 2.87 3.31 3.76 3.96 3.22 2.48
72 (22.2) SHC 13,070 12,830 12,460 12,340 8,430 5,610
71 76 (24.4) SHC 15,400 15,150 14,790 14,790 10,750 7,940
(21.7) 80 (26.7) SHC 17,840 17,600 17,360 17,230 13,200 10,380
84 (28.9) SHC 20,170 19,920 19,680 19,560 15,520 12,710
88 (31.1) SHC 22,490 22,250 22,000 21,880 17,840 15,030
TC 36,560 36,070 35,450 34,630 24,680 16,830
CI 2.97 3.42 3.88 3.98 3.22 2.48
75 76 (24.4) SHC 11,850 11,610 11,360 11,120 7,570 5,130
(23.9) 80 (26.7) SHC 14,300 14,050 13,810 13,560 10,020 7,570
84 (28.9) SHC 16,620 16,500 16,250 15,890 12,340 9,900
88 (31.1) SHC 18,940 18,820 18,580 18,210 14,660 12,220
TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h)

< Cooling Capacity >

1. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB
: Outdoor Ambient Temp. 95 °F (35 °C) DB
2.
3. Above data represents the value when the operation frequency of a compressor is fixed.
Above data does not take Freeze Prevention Protection during cooling operation into account.
For this reason, the value may vary from the actual cooling characteristics.
NOTE
22