9.3.1.3.Execute Adjustment
(In case of “OIS Adjustment”)
1.Perform step “9.3.1.1.” to “9.3.1.2.”, to reset the OIS flag status “F” (Set) to “0” (Reset)
2.Press “[ W ] side of the Zoom button” after Flag reset. OIS Adjustment screen is displayed on the LCD panel. (Refer to
3.Press the [ Shutter ] button.
The adjustment will start automatically.
4.When the adjustment is completed successfully, adjust- ment report menu appears with Green OK on the LCD monitor. (Refer to
9.3.1.4.Attention point during Adjustment
1.Step “9.3.1.3.” procedure shows OIS adjustment as an example. To perform the adjustment, refer to the “9.3.2. Adjustment Specifications” table which shows key point for each adjustment.
2.Do not move the light box, the camera or the chart while adjusting. If one of these is moved accidentally, start the adjustment again.
3.Do not press any buttons/keys until the default menu (Refer to
4.If the adjustment is interrupted accidentally, the alignment data may not be properly saved in the
9.3.1.5.Finalizing the Adjustment
1.Several adjustment flags can be reset (“F” into “0”) at the same time. In this case, when the adjustment has been completed, the screen will change showing the adjustment for the next item until all reset items are completed.
Also, when the [ Shutter ] button is pressed, the screen jump to the next adjustment item.
2.To cancel the adjustment mode while in the process of performing the adjustment, follow this procedures.
3.Operate the following, when escaping the Electrical Adjustment mode on the way.
(1)Press “[ Delete/Cancel ] button”.
(2)Press “[ RIGHT ] of Cursor button”.
NOTE:
•If adjustment is cancelled with above procedure, adjustment is not completed. Make sure to adjust it later.
•Adjustment software “DIAS” is able to control the status of the adjustment flags.
32