Setting up

Setting up

Cautions when setting up the interface box

zzWhen mounting the interface box to a rack or a table underside, use the supplied rack/table underside mounting bracket or the rack mounting bracket.

zzUse a torque screwdriver or torque wrench to tighten bolts to their specified tightening torques. Do not use tools such as electric screwdrivers or impact screwdrivers. Tightening screws with over their specified tightening torques will damage mount screw holes, failing to mount the interface box using brackets.

Right side

Supplied screws: Flat-head Phillips screw (M3)

Torque: 0.8 ± 0.2 N·m

Left side

Table underside mount screw hole

Rack mount screw hole

Mounting on the rack

1) Attach the supplied rack mounting bracket.

zzFix the rack mounting bracket to the rack mount screw holes on both sides of the interface box with supplied flat-head Phillips screws (3 pcs). Securely tighten the screws.

Rack mounting bracket

Rack/table underside mounting bracket

Rack mount

screw hole

2) Attach the supplied rack/table underside mounting bracket.

zzFix the rack mounting bracket to the rack mount screw holes on the both sides of the interface box with supplied flat-head Phillips screws (3 pcs).

ENGLISH - 15