Setting up
3) Fix to the rack by using the commercially available screws*1 (4 pcs).
*1: Use M5 or M6 screws for EIA standard rack. zzSecurely tighten the screws.
Attention
zzDuring attachment, be careful that the interface box does not slip.
zzBe sure to fix the cables connected to the connecting terminals and the supplied AC adaptor nearby such as the supports of the rack to avoid the cable and AC adaptor weights directly applied to the interface box.
zzBe sure that the temperature inside of the rack, of which the interface box is mounted, does not exceed 40°C (104°F).
zzWhen mounting the interface box on the rack, leave 1 U (44.45 mm, 1.75") space at the upper side of the interface box and be careful not to cover exhaust ports.
Mounting to the underside of the tabletop of the desk
1) Mount the supplied rack/table underside mounting bracket to the interface box (on the left and right).
zzMount the bracket to the table underside mount screw holes at the lateral side of the interface box with the supplied
zzBe sure to tighten at the specified torque.
Rack/table underside mounting bracket
Table underside mount
screw hole
2) Attach the AC adaptor and a mounting bracket for securing AC adaptor. zzFor the attachment procedures, refer to “Connecting the AC adaptor” ( page 23).
zzIf the mounting bracket for securing AC adaptor is attached after the interface box is attached to the table underside, excessive force may be applied to the mounting section on the table underside, which may cause damage of the table or deformation of the interface box.
3) Fix to the underside of the tabletop by using the commercially available screws or wood screws (4 pcs).
zzCheck that the tabletop is strong enough to bear the weight of the interface box. zzSecurely tighten the screws and the wood screws.
Attention
zzWhen mounting the interface box to the underside of the tabletop of the desk, request the mounting operation to the specialized engineer or to your dealer.
zzIf the connecting terminals on the rear side become invisible when the interface box is attached to the table underside, it is recommended to connect cables in advance before the interface box is attached to the table underside.
zzDuring attachment, be careful that the interface box does not slip. Failure to observe this may cause a flaw on the table.
zzWhen mounting to the underside of the tabletop of the desk, do not mount at a position, where an operator’s leg may collide. Mount screws being loosened may cause the device to fall down, which will lead to damage to or deformation of the device.
zzBe sure to fix the cables connected to the connecting terminals and supplied AC adaptors nearby such as the legs of the desk to avoid the cable and AC adaptor weights directly applied to the interface box.
zzFor heat release, leave 3 cm (1.2") or wider space at both sides of the interface box.
zzWhen using the interface box, do not place objects on the interface box. Be careful not to cover exhaust ports.
16 - ENGLISH