Symptom

Possible cause

 

 

The systolic pressure

• The hand with the cuff was held too low and

value or diastolic

not at heart level. (See page 9)

pressure value is high.

• The cuff was not attached properly. (See

 

page 9.)

 

• You moved your hand or body or you spoke

 

during measurement. (See page 9.)

 

 

The systolic pressure

• The hand with the cuff was held too high and

value or diastolic

not at heart level. (See page 9.)

pressure value is low.

• You moved your hand or body or you spoke

 

during measurement. (See page 9.)

 

 

The measured values

• Your posture was not the same for all

differ significantly.

measurements, or measurements were

 

taken without sufficient time in between.

 

Always wait approximately 5 minutes before

 

taking another reading, and above all, relax.

 

 

The measured value

• Blood pressure varies in response to

differs from that

minute changes in your mental state, such

measured by the doctor.

as your reaction to your doctor taking the

The measured value is

measurement. One way to check this is to

different for each

bring the unit to your doctor’s office and

measurement.

directly compare the readings taken by

 

your physician.

 

• Relax for at least 5 minutes and then take

 

another measurement.

 

 

Varying sounds and

• Changes in operating sounds and

pressurization speeds

pressurization speeds are normal and occur

occur during inflation of

due to the fact that measurements are

the cuff.

being made as the cuff is being inflated.

 

 

The measured value

• For persons with certain circulation problems,

obtained is different

there may be substantial differences in

from that measured at

blood pressure values measured at the

the upper arm.

upper arm versus at the wrist.

 

 

If the unit still appears to provide unusual or erroneous readings, consult your physician. If the unit does not appear to be functioning properly, contact Panasonic at 1-800-338-0552.

Specifications

Method of measurement:

Oscillometric System

 

 

Display:

Digital LCD

 

 

Measuring range:

Blood pressure: 0 - 280 mmHg

 

Pulse rate: 30 - 160 pulse/min.

 

 

Measurement accuracy:

Pressure: ±3 mmHg

 

Pulse rate: ±5%

 

 

Power source:

Two 1.5-volt alkaline (AAA/LR03) batteries

 

 

Operating environment:

10°C to 40°C (50°F to 104°F)

 

30% to 85% RH

 

 

Storage environment:

-20°C to 60°C (-4°F to 140°F)

 

10% to 95% RH

 

 

Wrist circumference

12.5 to 22.0 cm (5" to 8-3/4")

measurement range:

 

 

 

Dimensions (H#W#D):

58.0 #89. 0 #33.0 mm

 

(2-5/16" #3-1/2" #1-5/16")

 

 

Weight:

95 g (3.4 oz.) not including batteries

 

 

Specifications are subject to change without notice.