Panasonic EY6535-U1 specifications ↓OK Check Hammer Block

Models: EY6535-U1

1 13
Download 13 pages 35.42 Kb
Page 11
Image 11

EY6535-U1

<TROUBLE > No speed-control.

Weakness of vibration.

<CHECK > <CHECK FET.>

Even if FET block is defective, it can not be replaced individually. Replace whole switch block.

Shortcircuit (G: gate) and (S: source), and measure between it and (D: drain) with switch block.

NOTE:

*FET is sensitive against static electricity.

**The resistance value will vary dependent upon the measurement range of the tester.

OK

<CHECK SWITCH BLOCK.>

<CHECK ANVIL.>

Check wear condition. If no less than 1mm from the corner at (A) side or 0.5mm from the corner at (B) side, anvil is OK.

OK

<CHECK HAMMER BLOCK.>

Check whether hammer block rotates smoothly when moving shaft of hammer.

OK

<CHECK MOTOR.>

Measure no load rotation whether it is more than 1,900rpm with full charged battery pack.

< REMEDY >

NO Replace switch & FET

block.

NO Replace switch & FET

block.

NO Replace anvil.

NO Replace driving shaft

assembly.

NO Replace motor.

11

Page 11
Image 11