GENERAL SAFETY INFORMATION CONTINUED

WARNING

When this product is no longer being operated, please remove the product to prevent the possibility of falling.

Ceiling joist must be subjected to static load more than five times the weight of the product.

Do not install with a method which is not approved in the instructions.

Do not use this fan with any solid-state speed control device. Solid state controls may cause harmonic distortion which can cause motor humming noise.

This product must be properly grounded.

CAUTION

Do not install this ventilating fan where interior room temperature may exceed 104°F(40°C).

Prohibited

Make sure that the electric service supply voltage is AC 120V, 60Hz.

Follow all local electrical and safety codes, as well as the National

Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA).

Prohibited

Always disconnect the power source before working on or near the fan, motor, light fixture or junction box.

Protect the supply wiring from sharp edges, oil, grease, hot surfaces, chemicals or other objects.

Do not kink the supply wiring.

Provide make up air for proper ventilation.

For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

Do not install the unit where ducts are configured as shown in Fig.A.

Not for use in cooking area. (Fig.B)

Prohibited

Adaptor

Prohibited

(Cooking area)

Do not install above or

inside this area

45

45

The special-purpose or dedicated parts, such as mounting fixtures, must be used if such parts are provided.

 

Cooking

Floor

 

equipment

 

 

 

 

Fig. B

PLEASE READ PRIOR TO INSTALLING THIS FAN

Spot and Continuous Ventilation: These fans are designed to run continuously ensuring a healthy environment at low CFM levels 24 hours a day. By utilizing the optional CustomVent Multi-Speed module the fans are built to run continuously at a pre-set lower level (FV-05-11VKSL1 and FV-05-11VKL1: 0, 30, 40, 50, 60, 70, 80, 90, 100 CFM; FV-11-15VKL1: 0, 50, 60, 70, 80, 90, 100, 110, 120 CFM). The setting is dependent on the size of the house and the individual wishes of the homeowner. It is crucial that the installer pre-set the lower setting during the installation. Please refer to the chart below and the switch indication on page 6.

3

Page 3
Image 3
Panasonic FV-05-11VKSL1, FV-05-11VKL1, FV-11-15VKL1 Please Read Prior to Installing this FAN, Fig. B