INDICATION (PLUG ‘N PLAY FUNCTION DEVICES) CONTINUED
PLUG ‘N PLAY Modular Component Accessories
Sold Separately, Not Included With Base Model Fan
FV-CSVK1 Condensation Sensor module turns the base fan on or boosts to higher speed when humidity is detected when used in combination with the FV-VS15VK1. The Condensation Sensor works based on calculations from the Psychrometric Chart, or combination of Relative Humidity (RH) and Temperature. This allows the fan to anticipate the formation of condensation and automatically turn on when needed to expel humid air. The Condensation Sensor is pre-set to run for 20 minutes; it will then check the RH and Temperature to detect if the fan needs to run for another 20 minutes cycle.
FV-MSVK1 Motion Sensor module turns the base fan on or boosts to higher speed when motion is detected when using in combination with the FV-VS15VK1. The Motion Sensor is pre-set to run for 20 minutes; it will then re-check for movement; if detected the fan will run for another 20 minutes cycle. The Motion Sensor detects within the range shown below.
The distance that motion can be detected is limited to 10 feet (3m). The field of view of the sensor is 90°. (Room temperature is 25C).
FV-NLVK1 Nite-GloTMLED Night Light module automatically turns on when ambient light levels are met. Turning the dial on the Modular Nite-Glo Component to ‘DARK’ is ideal if the fan is in an isolated room with little ambient light from nearby rooms. Turning the dial to ‘BRIGHT’ is ideal if there is light spill from nearby rooms. (Note that it is necessary to connect wall switch when only plug in FV-NLVK1, fan can operate on high speed with wall switch control, fan can also operate on low speed when used in combination with the FV-VS15VK1.)
MOTION (PLUG ‘N PLAY FUNCTION DEVICES)
| PLUG ‘N PLAY Modular | PLUG ‘N PLAY Modular Component Accessories |
| Components used in | | | |
| Sold Separately, Not Included With Base Model Fan |
| Combinations |
| | | |
| FV-CSVK1 + FV-MSVK1 |
| | | | |
| | | | | Turns the fan on for 20 minutes when either |
| | | | |
| | | | | motion or excess humidity is detected. |
| | | | |
FV-CSVK1 + FV-VS15VK1
Cycles the fan to high speed from low speed for the amount of time selected on the Control Dial based upon detection of excess humidity.
FV-MSVK1 + FV-VS15VK1
Cycles the fan to high speed from low speed for the amount of time selected on the Control Dial based upon motion within the room.
Module FV-MSVK1, FV-CSVK1 (Not included)
INSIDE | | | OUTSIDE | | |
| | |
| | |
At low | When motion or | | Remains running |
excess humidity is | | at high speed until |
speed | detected, fan runs | | the delay time has |
| at high speed. | | passed. |
| | | | | | |
| Motion | Fan | Time delay |
| operation | operation |
| |
| | | |
| FV-CSVK1 only | Fan | 20 minutes |
| |
| FV-MSVK1 only | ON/OFF | time delay |
| | |
| | | |
| FV-CSVK1 + FV-VS15VK1 | Fan | Depend on |
| FV-VS15VK1 Time |
| FV-MSVK1 + FV-VS15VK1 | Hi/Low speed |