INDICATION (PLUG ‘N PLAY FUNCTION DEVICES) CONTINUED

PLUG ‘N PLAY Modular Component Accessories

Sold Separately, Not Included With Base Model Fan

FV-CSVK1 Condensation Sensor module turns the base fan on or boosts to higher speed when humidity is detected when used in combination with the FV-VS15VK1. The Condensation Sensor works based on calculations from the Psychrometric Chart, or combination of Relative Humidity (RH) and Temperature. This allows the fan to anticipate the formation of condensation and automatically turn on when needed to expel humid air. The Condensation Sensor is pre-set to run for 20 minutes; it will then check the RH and Temperature to detect if the fan needs to run for another 20 minutes cycle.

FV-MSVK1 Motion Sensor module turns the base fan on or boosts to higher speed when motion is detected when using in combination with the FV-VS15VK1. The Motion Sensor is pre-set to run for 20 minutes; it will then re-check for movement; if detected the fan will run for another 20 minutes cycle. The Motion Sensor detects within the range shown below.

The distance that motion can be detected is limited to 10 feet (3m). The field of view of the sensor is 90°. (Room temperature is 25C).

FV-NLVK1 Nite-GloTMLED Night Light module automatically turns on when ambient light levels are met. Turning the dial on the Modular Nite-Glo Component to ‘DARK’ is ideal if the fan is in an isolated room with little ambient light from nearby rooms. Turning the dial to ‘BRIGHT’ is ideal if there is light spill from nearby rooms. (Note that it is necessary to connect wall switch when only plug in FV-NLVK1, fan can operate on high speed with wall switch control, fan can also operate on low speed when used in combination with the FV-VS15VK1.)

MOTION (PLUG ‘N PLAY FUNCTION DEVICES)

PLUG ‘N PLAY Modular

PLUG ‘N PLAY Modular Component Accessories

Components used in

 

 

 

Sold Separately, Not Included With Base Model Fan

Combinations

 

 

 

FV-CSVK1 + FV-MSVK1

 

 

 

 

 

 

 

 

Turns the fan on for 20 minutes when either

 

 

 

 

 

 

 

 

motion or excess humidity is detected.

 

 

 

 

FV-CSVK1 + FV-VS15VK1

Cycles the fan to high speed from low speed for the amount of time selected on the Control Dial based upon detection of excess humidity.

FV-MSVK1 + FV-VS15VK1

Cycles the fan to high speed from low speed for the amount of time selected on the Control Dial based upon motion within the room.

Module FV-MSVK1, FV-CSVK1 (Not included)

Human active

Fan active

INSIDE

 

 

OUTSIDE

 

 

 

 

 

 

 

 

At low

When motion or

 

Remains running

excess humidity is

 

at high speed until

speed

detected, fan runs

 

the delay time has

 

at high speed.

 

passed.

 

 

 

 

 

 

 

Motion

Fan

Time delay

operation

operation

 

 

 

 

FV-CSVK1 only

Fan

20 minutes

 

FV-MSVK1 only

ON/OFF

time delay

 

 

 

 

 

FV-CSVK1 + FV-VS15VK1

Fan

Depend on

FV-VS15VK1 Time

FV-MSVK1 + FV-VS15VK1

Hi/Low speed

delay setting

 

 

 

7

Page 7
Image 7
Panasonic FV-05-11VKL1, FV-05-11VKSL1 Motion Plug ‘N Play Function Devices, Turns the fan on for 20 minutes when either