2.1 PT Programming

2.1.11SMDR & Maintenance Programming

[800]RS-232C Parameter—New Line Code

[800]

ENTER

Location

SELECT

 

 

1

(AUTO ANS/MESSAGE)

ENTER

END

CR+LF/CR

(HOLD)

 

[800] RS-232C Parameter—Baud Rate

[800]

ENTER

Location

2

SELECT

2400/4800/9600/END

19200/38400/57600/ ENTER 115200 bps

[800] RS-232C Parameter—Word Length

[800]

ENTER

Location

3

SELECT

END

7/8 bits

ENTER

 

[800] RS-232C Parameter—Parity Bit

[800]

ENTER

Location

4

SELECT

None/Mark/END

Space/Even/Odd ENTER

[800] RS-232C Parameter—Stop Bit Length

[800]

ENTER

Location

5

SELECT

END

1 bit/2 bits

 

ENTER

[801]External Modem Control

[801] Command No.

1–5

END

ENTER

ENTER

[802] SMDR Page Length

[802]

Page length

END

 

4–99 lines

ENTER

ENTER

 