LD (ALD)

5-(1). Electrical life test

(3 A 250 V AC, resistive load)

Change of pick-up and drop-out voltage

Change of contact resistance

Sample: ALD112, 6 pcs.

Operating speed: 20 cpm

Ambient temperature: room temperature circuit:

250V AC

12V DC

60Hz

G

NO COM

 

Ratio against the rated voltage, %V

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70

 

 

 

 

 

 

 

 

 

 

 

Pick-up volt

age

 

Max.

 

 

 

 

 

60

 

 

 

 

 

 

 

Min.

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drop-ou

t voltage

 

Max.

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min.

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

0

 

 

 

 

10

 

 

 

 

No. of operations, ×104

 

 

 

 

 

 

 

 

Contact resistance, mΩ

100

90

80

70

60

50

40

30

20

10

0

Max.

Min.

0

10

No. of operations, ×104

5-(2). Electrical life test

(3 A 30 V DC, resistive load)

Change of pick-up and drop-out voltage

Change of contact resistance

Sample: ALD112, 6 pcs.

Operating speed: 20 cpm

Ambient temperature: room temperature circuit:

12V DC

30V DC

G

NO COM

 

Ratio against the rated voltage, %V

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70

 

 

 

Pick-up

voltage

 

 

 

Max.

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min.

 

 

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

Drop-out voltage

 

 

Max.

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min.

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

0

 

10

 

 

20

 

 

 

 

 

No. of operations, ×104

 

 

 

 

 

 

 

 

 

Contact resistance, mΩ

100

90

80

70

60

50

40

30

20

10

0

Max.

Min.

0

10

20

 

 

No. of operations, ×104

 

 

 

 

For Cautions for Use, see Relay Technical Information .

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

Page 3
Image 3
Panasonic LD Relays (ALD) specifications For Cautions for Use, see Relay Technical Information