24
Control commands via LAN

When WEB Control administrator rights password is set (Protect mode)

Connection method

Obtain the IP address and port number (Initial set value = 1024) of the projector and 1)

make a request for connection to the projector.

Acquire the IP address from the menu screen of the projector, and the port number from the WEB c ontrol
page.
IP address : Obtain from MAIN MENU → [Network] → [Network st atus]
Port No. : Acquire from the WEB control “Detailed set up” → “Command port setting” page

There is a response from the projector.2)

Response data
Data section Blank Mode Blank Random number
section
Termination
symbol
“NTCONTROL”
(ASCII string)
‘ ’
0x20
‘1’
0x31
‘ ’
0x20
“zzzzzzzz”
(ASCII code hexadecimal
number)
(CR)
0x0d
9 bytes 1 byte 1 byte 1 byte 8 bytes 1 byte
Mode : 1 = Protect mode

Generate a 32-byte hash value from the following data using MD5 algorithm.3)

“xxxxxx:yyyyy:zzzzzzzz”
xxxxxx : Administrator rights user name for WEB CONTROL (Default user name is “admin1”)
yyyyy : Password of above administrator rights user (Default password is “panasonic”)
zzzzzzzz : 8 -byte random number obtained in Step 2

Command transmission method

Transmit using the following command format.
Transmitted data
Header Data section Termination symbol
Hash value
(See above
<Connection method>)
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
32 bytes 1 byte 1 byte Undened length 1 byte
Receive data
Header Data section Termination symbol
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
1 byte 1 byte Undened length 1 byte
Error response
Error message Termination symbol
“ERR1”
“ERR2”
“ERR3”
“ERR4”
“ERR5”
“ERR A”
Undened control command
Out of parameter range
Busy state or no-acceptable period
Timeout or no-acceptable period
Wrong data length
Password mismatch
(CR)
0x0d
4 bytes 1 byte