LAMP, TEMP and FILTER Indicators

Managing the indicated problems

If a problem should occur with the projector, the LAMP, TEMP and/or

 

FILTER indicators will inform you. Manage the indicated problems as

 

follow.

 

1.

Confirm the status of all indicators and projector, and switch off the

 

 

projector in proper way.

 

2.

Find out the cause of the problem by status of the LAMP, TEMP

POWER LAMP TEMP FILTER

 

and/or FILTER indicators.

3.

Follow the instruction for each indication below and solve the

 

 

problem.

 

4.Turn on the projector in the correct way and confirm the indicator is not indicating a problem any longer.

NOTE:

• If no problem is found or the problem remains, do not turn on the projector. Instead contact an Authorised Service Centre.

LAMP indicator

Indicator

Illuminating RED

Flashing RED

 

 

 

 

 

 

 

Problem

LAMP RUNTIME has

LAMP circuit failure, abnormal function or Lamp unit is damaged.

reached 4 800 hours.

 

 

 

 

 

Lamp unit will run out

The MAIN POWER is

 

 

Cause

switched on again before

LAMP circuit failure,

 

soon and needs to be

Lamp unit is damaged.

the Lamp unit is cooled

abnormal function.

 

replaced.

 

 

enough.

 

 

 

 

 

 

 

 

Let the Lamp unit cool

 

 

Remedy

See “Replacing the Lamp

down and turn on the

Contact an Authorised

See “Replacing the Lamp

unit” on page 43.

MAIN POWER after

Service Centre.

unit” on page 43.

 

 

 

90 seconds..

 

 

 

 

 

 

 

TEMP indicator

Indicator

Illuminating RED while projecting and the alert will be displayed.

 

Flashing RED and POWER is turned off

 

 

 

 

 

Problem

The temperature inside and/or outside the projector is abnormally high.

 

 

 

 

 

 

Cause

The ventilation openings

The room temperature is

The ARF is excessively

The projector is located at

dirty and the ventilation is

1 400 - 2 700 m (4 593 -

are covered.

too high.

 

poor.

8 858 ft).

 

 

 

 

Remove the object(s)

Reinstall the projector in

Replace the ARF in the

Turn on the projector*1

Remedy

from the ventilation

temperature controlled

proper method. See

and set the ALTITUDE to

openings or clear around

 

place. See page 50.

page 42.

HIGH. See page 37.

 

the projector.

 

 

 

 

 

 

 

 

 

*1. The projector will perform only 2 minutes with OFF setting at high elevation.

FILTER indicator

When the FILTER indicator is flashing GREEN, the ARF is normally rolling up.

Indicator

Illuminating RED

Flashing RED

Illuminating ORANGE

Flashing ORANGE

 

 

 

 

 

Problem

FILTER REMAINING has

The projector cannot

The ARF cannot operate

FILTER REMAINING has

turned yellow. See

turned red. See page 36.

detect the ARF.

properly.

 

page 36.

 

 

 

 

Cause

 

 

Foreign object is blocking

ARF is running out and

ARF has been run out.

ARF is not attached.

the remaining time is

 

 

 

the ARF operation.

about 240 hours..

 

 

 

 

 

See “Replacing the ARF

 

Remove the foreign

 

Remedy

 

object or contact an

Prepare the ARF for

(Auto Rolling Filter)” on

Attach the ARF.

Authorised Service

replacement.

 

page 42.

 

 

 

Centre.

 

 

 

 

 

 

 

 

 

 

Maintenance

ENGLISH - 41

Page 41
Image 41
Panasonic PT-F200E manual LAMP, Temp and Filter Indicators, Managing the indicated problems, Lamp indicator, Temp indicator