'Install the lamp unit cover, and
then use a Phillips screwdriver
to securely tighten the lamp
unit cover fixing screws.
(Connect the mains lead.
)Press the POWER button so
that a picture is projected onto
the screen.
*Press the MENU button to
display the “MAIN MENU”, and
then press the For Gbutton
to select “OPTION”.
ENGLISH-57
Care and maintenance
+
Press the ENTER button to
display the “OPTION” menu, and
then press the For Gbutton to
select “LAMP RUNTIME”.
,Press and hold the ENTER
button for approximately 3
seconds.
The “LAMP RUNTIME” will
change to “TIME RESET
[POWER OFF]”.
-Turn off the power and
disconnect the mains lead.
This will reset the cumulative
usage time for the lamp unit to “0”.
Refer to page 26 for details on
how to turn off the power.
MENU
KEYSTONE
PICTURE
POSITION
INDEX WINDOW
SHUTTER
VOLUME
LANGUAGE
OPTION
SECURITY
NETWORK
SELECT
ENTER EXIT
OPTION
BACK COLOR BLUE
FRONT/REAR FRONT
DESK/CEILING DESK
FAN CONTROL STANDARD
LAMP POWER HIGH
TIME RESET [POWER OFF]
FUNC 1 DAYLIGHT
CONTROL KEY ON
AUTO POW.OFF DISABLE
POWER MEMORY ON
SELECT RETRN
NOTE:
BBe sure to install the lamp unit
and the lamp unit cover
securely. If they are not securely
installed, it may cause the
protection circuit to operate so
that the power cannot be turned
on.
NOTE:
BIf the MENU button is pressed,
the lamp time resetting screen
will be cancelled.
NOTE:
BIf the mains lead was
disconnected during projection
when the projector was used
the last time, projection will
start after the mains lead is
connected (when “POWER
MEMORY” in the “OPTION”
menu is set to “ON”). Refer to
page 48 for details.
OPTION
BACK COLOR BLUE
FRONT/REAR FRONT
DESK/CEILING DESK
FAN CONTROL STANDARD
LAMP POWER HIGH
LAMP RUNTIME 1820H
FUNC 1 DAYLIGHT
CONTROL KEY ON
AUTO POW.OFF DISABLE
POWER MEMORY ON
SELECT RETRN