Panasonic SJ-MJ88 manual Laser Power Adjustment

Models: SJ-MJ88

1 62
Download 62 pages 61.36 Kb
Page 27
Image 27

Adjustment mode

Display

Laser power adjustment

T0E

Off-set automatic adjustment

T1E

Magneto-optical disc automatic adjustment

T2E

Playback-only disc automatic adjustment

T3E

Jitter meajurement (74minutes)

T4E

Jitter meajurement (60 minutes)

T5E

Destination change

T6E

Off-set automatic adjustment value check

T7E

Magneto-optical disc automatic adjustment

T8E

value check

 

Playback-only disc automatic adjustment value

T9E

check

 

Error rate measurement (double velocity)

TAE

ROM collection

TBE

DRAM check

TCE

Aging

TDE

Tilt measurement

TEE

PWB inspection

TFE

*In the display of T0E ~ TFE shown above, you must adjust T0E , T1E , T2E and T3E . You must perform the adjustment by observing the order T0E 6.2.2. Laser Power Adjustment T1E Manual background T2E Manual background T3E .

6.2.2. Laser Power Adjustment

Adjust each laser power: read power for reading (play).

6.2.2.1. Set the Unit to the Adjustment Mode Cautions

About handling the optical pickup and the magnetic head.

-The optical pickup is structured precisely; therefore, it is very fragile. Be

-

-

careful not to touch it with the edge of the laser power meter. Do not touch the lens.

The sensor of the laser power meter is a very fine part. Be careful not to touch it to the optical pickup lens.

The focus point of the laser reaches to 356°F. Therefore, avoid adjusting using laser power for a long time because the sensor of the laser power meter may be burned.

-Do not set the unit to the laser power adjustment mode with the MD loaded. Doing so may result in damage to the MD.

27

Page 27
Image 27
Panasonic SJ-MJ88 manual Laser Power Adjustment