Panasonic SJ-MJ88 manual Specified range 600 W±10% Caution

Models: SJ-MJ88

1 62
Download 62 pages 61.36 Kb
Page 29
Image 29

4.Press the [Specified range: 600  W±10%] Caution: key of the remote controller (“LD ” changes to “LP ” of the LCD).

5.Set the laser power at 600 Manual background W±10% by using VOL+ and VOL- key of the remote controller.

[Specified range: 600 Manual background W±10%] Caution:

Proceeding on to the subsequent adjustment procedure with the read power exceeding 600 Manual background W±10% will result in damage to the optical pickup.

6.Set the laser power with the Manual background key of the remote controller (“LP ” changes to “LDOK ” in the LCD).

7.Press the Manual background key of the remote controller (“LDOK ” changes to “T0E ” on the LDC.

8.Remove the laser power meter. Laser power adjustment is finished.

[REFERENCE]

<For use of MD cartridge type laser power meter>

We recommend you to use a sensor type laser power meter for laser power adjustment of this set.

But if available is a MD cartridge type only, follow the procedure below.

1.Disassemble the unit so that only the mechanism unit and the printed circuit board are exposed. (as shown in Fig. 8 )

2.Set the laser power meter cartridge. (as shown in Fig. 8 )

3.Set the battery and attach and secure the battery cover with a rubber band. (as shown in Fig. 9 )

4.Follow the steps for “6.2.1. Enter the adjustment mode”. (Subsequent procedures are the same as those for the sensor type.)