4.Press the key of the remote controller (“LD ” changes to “LP ” of the LCD).
5.Set the laser power at 600 W±10% by using VOL+ and VOL- key of the remote controller.
[Specified range: 600 W±10%] Caution:
Proceeding on to the subsequent adjustment procedure with the read power exceeding 600 W±10% will result in damage to the optical pickup.
6.Set the laser power with the key of the remote controller (“LP ” changes to “LDOK ” in the LCD).
7.Press the key of the remote controller (“LDOK ” changes to “T0E ” on the LDC.
8.Remove the laser power meter. Laser power adjustment is finished.
[REFERENCE]
<For use of MD cartridge type laser power meter>
We recommend you to use a sensor type laser power meter for laser power adjustment of this set.
But if available is a MD cartridge type only, follow the procedure below.
1.Disassemble the unit so that only the mechanism unit and the printed circuit board are exposed. (as shown in Fig. 8 )
2.Set the laser power meter cartridge. (as shown in Fig. 8 )
3.Set the battery and attach and secure the battery cover with a rubber band. (as shown in Fig. 9 )
4.Follow the steps for “6.2.1. Enter the adjustment mode”. (Subsequent procedures are the same as those for the sensor type.)
Fig. 8
29