Panasonic TH50PHW5, TH-50PHD5, TH-42PHD5, TH-42PHW5 manual Main Power Supply, Power Factor Control

Models: TH-50PHD5 TH-42PHD5 TH50PHW5 TH-42PHW5

1 91
Download 91 pages 8.91 Kb
Page 32
Image 32

Main Power Supply

Figure 30

Power Factor Control

The power factor control circuit operates like a boost regulator. The incoming AC voltage, after being switched on, enters the rectifier D402 where it is converted to DC. The Power Factor Control (PFC) circuit converts the DC level to 400Vdc.

The negative side of the bridge rectifier D402 connects to ground via a resistor. As current flows through the resistor, the resulting voltage drop enters pin 5 of connector P19/P19A of the power factor control circuit board. The power factor control circuit board is a switching control oscillator circuit which boosts the input voltage at pin 2 of the transformer T401 to 400Vdc. As the pulses are output at pin 4 of connector P19/P19A, the transistors Q400~Q405 are switched On/Off controlling the charge and discharge time of the inductor L401. The output voltage is monitored via pin 11 of the connector P19/P19A. The resistor R548 adjusts the output voltage to 400Vdc. The 400Vdc output to pin 2 of the transformer T401 subsequently enters the drain of transistor Q416.

32

Page 32
Image 32
Panasonic TH50PHW5, TH-50PHD5, TH-42PHD5, TH-42PHW5 manual Main Power Supply, Power Factor Control