ECO MODE SETTINGS
Select “ECO MODE SETTINGS” in “SETUP” menu and pressbutton.
ECO MODE SETTINGS
|
|
|
|
| ECO MODE |
| CUSTOM |
| POWER SAVE | OFF | |
| STANDBY SAVE | ON | |
| PC POWER MANAGEMENT | OFF | |
| OFF | ||
| NO SIGNAL POWER OFF | DISABLE | |
|
|
|
|
1 select
2 adjust
ECO MODE
CUSTOM: The menu of power consumption reduction is individually set.
ON: The following fixed values are set to the menu of power consumption reduction. Individual setting is not available.
POWER SAVE: SENSOR | |
STANDBY SAVE: ON | NO SIGNAL POWER OFF: ENABLE |
PC POWER MANAGEMENT: ON |
|
Using Remote Control
When is pressed, the “ECO MODE” setting changes.
|
|
|
|
| ECO MODE | ON |
|
|
|
|
|
Custom settings
The menu of the power consumption reduction is individually set. This setting is enabled when “ECO MODE” is set to “CUSTOM”.
POWER SAVE
When this function is turned ON, luminous level of the Plasma Display is suppressed, so power consumption is reduced. SENSOR: The luminous level of the Plasma Display is automatically adjusted according to the viewing environment.
STANDBY SAVE
When this function is turned ON, power consumption of the microcomputer is reduced during power supply standby (see page 16, 19, 20), so standby power of the set is reduced.
PC POWER MANAGEMENT
When this function is set to ON, it operates under the following conditions to turn the power on or off automatically. When no pictures (HD/VD sync signals) are detected for 30 or so seconds during PC signal input:
→Power is turned off (standby); the power indicator lights up orange. When pictures (HD/VD sync signals) are subsequently detected:
→Power is turned on; the power indicator lights up green.
Notes:
•This function operates only during PC signal input.
•This function is effective when “SYNC” is set to “AUTO”, “COMPONENT /
DVI-D POWER MANAGEMENT
When this function is set to ON, it operates under the following conditions to turn the power on or off automatically. When no pictures (sync signal) are detected for 30 or so seconds during DVI signal input:
→Power is turned off (standby); the power indicator lights up orange. When pictures (sync signal) are subsequently detected:
→Power is turned on; the power indicator lights up green.
Notes:
•This function operates only during DVI signal input.
•This function is invalid during input from
•Depending on the type of terminal board equipped, this function may be invalid.
NO SIGNAL POWER OFF
Equipment power supply is turned OFF when there is no signal.
When this is set to “ENABLE”, the power supply of the unit goes Off 10 minutes after the input signals stop.
43