Setup for input signals

Select the Signal from the “Setup” menu during RGB or PC input signal mode.

Press to select each item.

Press to adjust.

The following operation methods are the same for both the Signal [RGB] and Signal [PC].

SYNC

(TH-50PHD3 only)

Signal

 

[

Component

]

Clamp position

 

 

 

 

Signal

 

 

[ RGB

]

Sync

 

 

H & V

 

Pull-in range

 

 

Narrow

 

Clamp position

 

 

 

 

H-Freq.

31.5

kHz

 

 

V-Freq.

60.0

Hz

 

 

Signal

 

[

PC

]

Sync

 

H & V

 

 

Pull-in range

 

Narrow

 

 

Clamp position

 

 

 

 

H-Freq.

31.5

kHz

 

 

V-Freq.

60.0

Hz

 

 

Setting RGB sync signal setting:

Confirm that the input is set to RGB input (this setting is valid only for RGB input).

H&V: The H and V sync signals are input from the HD/VD (BNC) connector.

On G: Uses a synchronized signal on the Video G signal, which is input from the G (BNC) connector.

On VIDEO: Compatible with the scart plug (Europe)

The composite video signal input from the VIDEO input terminal is used by dividing the sync signals.

Sync

H & V

Sync

on G

Sync

on VIDEO

Setting PC sync signal setting:

Confirm that the input is set to PC input (this setting is valid only for PC input). H&V: The H and V sync signals are input from the HD/VD (BNC) connector.

ON G: Uses a synchronized signal on the Video G signal, which is input from the G (BNC) connector.

Pull-in range

Sets the width for different frequencies.

(This setting is the same for both Signal [RGB] and Signal [PC].)

Clamp position

Adjusts the clamp position.

The following operation methods are the same for “Signal” menu during Component (TH-50PHD3 only), RGB and PC input signal mode.

Normally, these adjustments are set to appropriate levels and therefore do not need to be altered.

Pull-in

range

Narrow

Pull-in

range

Wide

Clamp position

H-Freq. (kHz)/V-Freq. (Hz)

Displays the H (horizontal)/V ( vertical) frequencies.

This display is valid only for RGB input and PC input. Display range:

Horizontal 15.5 - 110 kHz Vertical 48 - 120 Hz

H-Freq. V-Freq.

31.5

60.0

kHz Hz

32

Page 32
Image 32
Panasonic TH 50PHD3, TH-50PHW3 manual Pull-in range, Clamp position, Freq. kHz/V-Freq. Hz