Panasonic TN Relay manual Reference Data, Specifications, Maximum switching capacity, Life curve

Models: TN Relay

1 5
Download 5 pages 41.91 Kb
Page 3
Image 3
2. Specifications

TN

3) 2 coil latching

 

 

 

Nominal operating

Coil resistance

 

Nominal operating

 

Nominal coil

Set voltage

Reset voltage

current

 

Max. allowable voltage

[±10%] (at 20°C 68°F)

power

voltage

(at 20°C 68°F)

(at 20°C 68°F)

[±10%] (at 20°C 68°F)

(at 20°C 68°F)

 

 

 

 

 

 

 

 

Set coil

Reset coil

Set coil

Reset coil

Set coil

Reset coil

 

 

 

 

 

 

 

 

 

 

 

3V DC

 

 

66.7mA

66.7mA

45

45

 

 

 

 

 

 

 

 

 

 

 

 

 

4.5V DC

 

 

44.4mA

44.4mA

101.2

101.2

 

 

 

 

 

 

 

 

 

 

 

 

 

5V DC

75%V or less of

75%V or less of

40mA

40mA

125

125

200mW

200mW

150%V of

6V DC

33.3mA

33.3mA

180

nominal voltage

nominal voltage*

nominal voltage*

180

 

 

 

 

9V DC

22.2mA

22.2mA

405

405

 

 

 

(Initial)

(Initial)

 

 

 

12V DC

 

 

16.7mA

16.7mA

720

720

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24V DC

 

 

12.5mA

12.5mA

1,920

1,920

300mW

300mW

120%V of

 

 

nominal voltage

 

 

 

 

 

 

 

 

 

 

*Pulse drive (JIS C 5442-1986)

 

 

 

 

 

 

 

 

 

2. Specifications

Characteristics

 

Item

Specifications

 

 

 

 

 

Arrangement

 

2 Form C

 

 

 

Contact

Initial contact resistance, max.

Max. 60 m(By voltage drop 6 V DC 1A)

 

 

 

 

 

Contact material

 

Ag+Au clad

 

 

 

 

Nominal switching capacity (resistive load)

1 A 30 V DC, 0.5 A 125 V AC

 

 

 

 

Max. switching power (resistive load)

30 W (DC), 62.5 VA (AC)

 

 

 

 

Max. switching voltage

110 V DC,125 V AC

 

 

 

Rating

Max. switching current

1 A

 

 

 

Min. switching capacity (Reference value)*1

10A 10mV DC

 

 

 

 

 

 

Nominal operating

Single side stable

140 mW (3 to 12 V DC), 200 mW (24 V DC), 300 mW (48 V DC)

 

 

 

 

1 coil latching

100 mW (3 to 12 V DC), 150 mW (24 V DC)

 

power

 

 

 

 

2 coil latching

200 mW (3 to 12 V DC), 300 mW (24 V DC)

 

 

 

 

 

 

 

Insulation resistance (Initial)

Min. 1,000M(at 500V DC)

 

Measurement at same location as “Initial breakdown voltage” section.

 

 

 

 

Breakdown voltage

Between open contacts

750 Vrms for 1 min. (Detection current: 10 mA)

 

Between contact and coil

1,000 Vrms for 1 min. (Detection current: 10 mA)

 

(Initial)

 

Between contact sets

1,000 Vrms for 1 min. (Detection current: 10 mA)

 

 

Electrical

Surge breakdown

Between open contacts

1,500 V (10160s) (FCC Part 68)

characteristics

voltage (Initial)

 

 

 

 

 

 

 

Temperature rise (at 20°C 68°F)

Max. 50°C

 

(By resistive method, nominal voltage applied to the coil; contact carrying current: 1A.)

 

 

 

 

 

 

 

Operate time [Set time] (at 20°C 68°F)

Max. 3 ms [Max. 3 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)

 

 

 

 

 

Release time [Reset time] (at 20°C 68°F)

Max. 3 ms [Max. 3 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)

 

(without diode)

 

 

 

 

Shock resistance

Functional

Min. 490 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)

Mechanical

Destructive

Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)

 

characteristics

 

Functional

 

Vibration resistance

10 to 55 Hz at double amplitude of 3 mm (Detection time: 10 s.)

 

Destructive

10 to 55 Hz at double amplitude of 5 mm

 

 

Expected life

Mechanical

 

Min. 108 (at 180 cpm)

Electrical

 

Min. 2105 (1 A 30 V DC resistive), Min. 105 (0.5 A 125 V AC resistive) (at 20 cpm)

 

 

 

Conditions for operation, transport and storage*2

Ambient temperature: –40°C to 70°C –40°F to 158°F;

Conditions

Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)

 

 

 

Max. operating speed (at rated load)

20 cpm

 

 

 

 

Unit weight

 

 

Approx. 1.5 g .053 oz

 

 

 

 

Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. (SX relays are available for low level load switching [10V DC, 10mA max. level])

*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.

REFERENCE DATA

1. Maximum switching capacity

DC load (cosϕ=1)

REFERENCE DATA AC load (cosϕ=1)

A

 

 

 

current,

1.0

 

 

 

 

 

Switching

0.5

 

 

0.4

 

 

0.3

 

 

 

 

 

 

0.2

 

 

 

30

100

200

 

 

Switching voltage,V

 

2. Life curve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

30 V DC resistive load

 

 

 

10

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of operations,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

125 V AC resistive load

 

 

No.

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0.5

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

Switching current, A

 

 

 

 

 

 

 

 

3. Mechanical life

Tested sample: TN2-12V, 10 pcs.

 

 

%V

100

 

 

 

 

 

 

 

 

 

voltage,

90

 

 

 

 

80

 

 

 

 

 

 

 

 

 

rated

70

 

Pick-up voltage

 

 

 

 

 

 

 

 

 

 

 

the

60

 

 

 

Max.

 

 

 

 

 

against

50

 

 

 

Min.

 

 

 

 

40

 

 

 

 

Ratio

 

 

 

 

30

 

Drop-out voltage

Max.

 

20

 

 

 

 

 

 

 

 

 

10

 

 

 

Min.

 

 

 

 

 

 

0

10

100

1,000

10,000

 

 

 

 

 

No. of operations, 104

 

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

Page 3
Image 3
Panasonic TN Relay manual Reference Data, Specifications, Maximum switching capacity, Life curve, Mechanical life