23
S-REGISTERS (continued)
Register Description Factory Setting Range
S54 V.54 Device Type 0 0=Peripheral; 1=Intermediate
S55 Access from Remote 0 0=Enable; 1=Disable
S56 Remote Access Password 00 00–99
1st and 2nd digits
S57 Remote Access Password 00 00–99
3rd and 4th digits
S58 Remote Access Password 00 00–99
5th and 6th digits
S59 Remote Access Password 00 00–99
7th and 8th digits
S61 CT111 Rate Control 0 0=Disable; 1=Fallback 1; 2=Fallback 2
S62 V.25bis Coding 0 0=ASCII; 1=EBCDIC
S63 V.25bis Idle Character 0 0=Mark; 1=Flag
S64 V.25bis New Line Character 0 0=CR+LF; 1=CR; 2=LF
S65 Line Current Disconnect 0 0=Enable (>8 msec); 1=Enable (>90 msec);
2=Disable
S66 NMS Call Messages 0 0=Call Connect & Progress; 1=Disable;
2=Call Connect Only; 3=Call Progress Only
S67 Directory Location 1 Callback 0 0=Disable; 1=Enable
S69 Make Busy Via DTR 0 0=Disable; 1=Enable
S74 Network Position 0 0=Tributary; 1=Control
S75 Network Management Address 255 0–255 (001–256)
S76 V.32bis Dial Autorate 0 0=Enable; 1=Disable; 2=Start at 4800 bps;
3=Start at 9600 bps
S77 DTR Alarm Reporting 0 0=Disable; 1=Enable
S78 V.32bis Dial Automode 0 0=Enable; 1=Disable; 2=System85
S80 No Data Disc Trigger Signal 3 0=RX or TX; 1=TX; 2=RX; 3=TX and RX
S81 Leased Line Signal Quality Retrain 0 0(Disable) or 1–5 seconds
S82 V.32bis Leased Autorate 0 0=Enable; 1=Disable
S84 AT Command Mode 0 0=Normal; 1=No Error; 2=No Strap or ERROR
S85 Fast Disconnect 0 0=Disable; 1=Enable
S88 Straps When Disconnected 0 0=No Change; 1=Reload; 2=Reload, No Change
S89 V.42 ARQ Window Size Increase 0 0(6 frames) – 9(15 frames)
S90 DTE Rate = VF Rate 0 0=Disable; 1=Enable
S91 Cellular Enhancements 0 0=Disable; 1=Enable
S93 RJ11 Cellular Adapt 0 0=Disable; 1=Enable