Removing/Replacing a Card

Card removal procedures differ, depending on whether you are removing the APM or I/O card.

NOTE:

You can insert or remove the APM and its associated I/O card without powering off the equipment and interrupting data flow through other cards in the network.

Removing/Replacing an APM

1.Remove the housing's bezel, if applicable. See the installation instructions that came with your housing for information.

2.Remove the captive screws from the ejector latches on the front of the housing.

3.Press open the ejector latches to disengage the card from the midplane.

4.Supporting the card by its edges, pull straight out until the card clears the housing.

5.Refer to Steps 3±5 of Installing the APM on page 6.

If the slot . . .

Then the . . .

 

 

Was previously unassigned

Configuration settings are the factory

 

defaults and are accessible from SNMP

 

and the user interface.

 

 

Was previously assigned to the same

Existing configuration settings are used

type of APM

and are accessible from SNMP and the

 

user interface.

 

 

Previously contained a different type of

System generates a Module

APM

Misconfiguration alarm for the given

 

slot. See the Technical Reference for

 

procedures in this situation.

 

 

Removing/Replacing an I/O Card

1.Remove the APM from the housing (see Removing/Replacing an APM).

2.Remove the cables from the I/O card.

3.Using a screwdriver, loosen the upper and lower captive screws fastening the card to the housing's frame.

4.Gently pull the I/O card away from the midplane until it clears the housing.

5.Align the replacement card with the upper and lower tracks of the slot. Push gently towards the midplane until it stops and you cannot push the card any further.

7

Page 7
Image 7
Paradyne 9109 OCU-DP technical manual Removing/Replacing a Card, Apm