Additional Information

LED Indicators

LED

 

State

 

Indication

 

Additional Information

 

 

 

 

 

 

 

100

 

solid green

 

Fast Ethernet connection

 

If the 100 LED is illuminated, the Lnk LED will also be illuminated.

 

 

 

 

(100 Mbps) is established

 

 

 

 

no

 

no Fast Ethernet

 

If the 100 LED remains unlit but the Lnk LED is illuminated then a link has

 

 

illumination

 

connection

 

been established at 10 Mbps rather than 100 Mbps.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Act

 

flashing

 

Ethernet activity

 

Traffic is flowing without any problems.

 

 

amber

 

 

 

 

 

 

solid amber

 

heavy traffic

 

 

 

 

no

 

no Ethernet activity

 

Either there is no Ethernet link or a link exists but there is no activity.

 

 

illumination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lnk

 

solid green

 

Ethernet connection is

 

If the Lnk LED is illuminated but not the 100 LED then a 10 Mbps link has

 

 

 

 

established

 

been established. If the 100 LED is also illuminated, then a 100 Mbps link

 

 

 

 

 

 

has been established.

 

 

no

 

no Ethernet connection

 

The 100 and Act LEDs will remain unlit by default.

 

 

illumination

 

 

 

 

 

 

 

 

 

 

 

Regulatory Compliance

The following regulatory compliance information applies to the UIM-10/100 as installed in a Mini DSLAM chassis or as affixed to a MUM installed in an IP DSLAM chassis.

FCC Regulatory Compliance Information for Class A Equipment

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Caution: Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.

Industry Canada Regulatory Compliance Information for Class A Equipment

This Class A digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada.