TROUBLESHOOTING GUIDE | 20 |
|
|
Your Parasound P 3 Preamplifier requires no periodic maintenance and has no
If this fuse blows, please contact Parasound Technical Service for further advice.
TROUBLE | PROBABLE CAUSE | REMEDY |
No power | Power cord is disconnected | Connect power cord |
| Voltage selector switch is in the | Make sure the Voltage selector switch is in the |
| wrong position | correct position for your region |
P 3 will not turn on with | AC fuse is blown | Replace fuse with one of the same value |
DC trigger voltage | DC trigger source wired with reverse | Check polarity of the DC trigger source with |
| polarity or voltage too low | a voltmeter |
Power but no sound | Volume control turned down | Increase the volume control setting |
| Bad connection to power amplifier | Check the output connections |
| External Loop jumpers are missing | Replace External Loop jumpers |
| P 3 is muted | Press Mute button or adjust the Volume knob |
|
| or remote buttons to unmute the P 3 |
Distorted sound through | Damaged speaker | Exchange the left and right speaker cables. |
speakers. |
| If the same speaker is distorted, the speaker is |
|
| damaged. If not, the problem may be with your |
|
| power amplifier or further up the signal path |
| Problem with the power amplifier or | Exchange the left and right P 3 output cables. |
| source component | If distortion stays in the same channel, the |
|
| problem is after the preamplifier |
| The P 3 Balance is adjusted all the | |
| way to the left or right |
|
| Ground loop from cable TV | Move the ground switch on the power amplifier |
|
| to its lift position. Install a cable isolation device |
|
| such as the Xantech 634 Ground Breaker. |
|
| www.xantech.com |
|
|
|
Hum and/or buzz through | Ground loop between the P 3 and | Move the ground switch on the power amplifier |
speakers | power amplifier | to its lift position. |
| Ground loop within equipment rack | Install nylon shoulder washers on both sides of |
|
| the |
|
| prevent the P 3 from making any |
|
| contact with the rack |
| Other ground loop | Contact Parasound Technical Service |
|
|
|