Other Rear Panel Connections

IR Input

Your P 5 is compatible with most popular infrared repeater systems for remote control operation from another room or when the P 5 is installed in a cabinet where its remote handset signals cannot reach its front panel remote control sensor. The External Remote Input connector is a standard 1/8” (3.5 mm) mono “mini” jack. The center conductor (plug tip) is for signal and the outer conductor (plug sleeve) is for ground. Your Authorized Parasound dealer or custom installer can recommend a compatible IR repeater system.

IR Loop Output

The loop output offers a convenient way to daisy chain an IR signal to another piece of equipment. Whatever IR control signal is present at the rear panel IR Input jack will also be present at the IR Loop Out jack.

AC Power Cord

The AC cord supplied with your P 5 is a high quality IEC type cord. If possible, plug your P 5 into the same AC outlet that your source components and power amplifier are plugged into. If different AC outlets are used for the P 5 and these other components the ground potential may be higher or lower between the outlets, resulting in audible hum.