| Power Amplifier f. |
Installation Manual | Series EC106 |
|
|
Electronic module for the control of proportional pressure or flow valves.The
Features
•Processing and amplification of externally sup-
plied positive commands into output signals for the control solenoid.
• Up to 6 independent channels for the control of up to 6 valves.
• Each channel is equipped with a slide switch for selection of pressure or flow valve operation.
• Ramp function
• Pulsed low loss amplifier power stages with supporting constant current control for constant, temperature independent solenoid forces.
• Dither generator with applied frequency to improve static characteristics.
Characteristics
Design |
| 2 channels |
| 4 channels |
| 6 channels |
Supply voltage | [V] |
| 24 ±10% |
|
| |
Power consumption max. | [VA] | 70 |
| 125 |
| 190 |
Command voltage | [VDC] |
| 0...+10 |
|
| |
Reference output | [VDC] |
|
| 10 ±5% / max. 100mA |
| |
Solenoid output current, max. | [A] | 2 x 1.3 |
| 4 x 1.3 |
| 6 x 1.3 |
Ramps | [s] |
| 0.01...10 |
|
| |
Ambient temperature | [°C] |
| 0...+70 |
|
| |
Connection |
|
| 48pole male connector, DIN 41612F |
| ||
Cable connection |
| Supply connections + valve: AWG15; command inputs AWG20 | ||||
Fuse DIN 41571 |
| 4A medium lag |
| 6.3A medium lag |
| 10A medium lag |
Ordering Code
EC
106
Electronic Module | Number of | Module Type | Design |
for | Channels | Amplifier, | Series |
Valves |
| switchable, |
|
DSA, DWE, DWU |
|
| |
RE*W, TDA*LAF, |
| valves, Ramps |
|
TEA*LAF |
|
|
|
Code | Quantity |
02 | 2 |
044
066
IA EC106 UK.INDD RH 02.06
3 | Parker Hannifin GmbH & Co. KG |
Hydraulic Controls Division