TROUBLESHOOTING TABLE

WARNING: Always stop unit and disconnect spark plug before performing any of the recommended remedies below other than remedies that require operation of the unit.

TROUBLE

CAUSE

REMEDY

Engine will not

1.Engine flooded.

1.See “Starting Instructions.”

start.

2.Fuel tank empty.

2.Fill tank with correct fuel mixture.

 

3.Spark plug not firing.

3.Install new spark plug.

 

4.Fuel not reaching carburetor.

4.Check for dirty fuel filter; replace.

 

 

Check for kinked or split fuel line;

 

5.Compression low.

repair or replace.

 

5.Contact an authorized service dealer.

Engine will not

1.Fuel not reaching carburetor.

1.Check for dirty fuel filter; replace.

idle properly.

 

Check for kinked or split fuel line;

 

2.Carburetor requires adjustment.

repair or replace.

 

2.Contact an authorized service dealer.

 

3.Crankshaft seals worn.

3.Contact an authorized service dealer.

 

4.Compression low.

4.Contact an authorized service dealer.

Engine will not

1.Air filter dirty.

1.Clean or replace air filter.

 

accelerate,

2.Fuel not reaching carburetor.

2.Check for dirty fuel filter; replace.

lacks power, or

 

Check for kinked or split fuel line;

dies under a

3.Spark plug fouled.

repair or replace.

3.Clean or replace spark plug; re-gap.

load.

4.Spark arresting screen clogged.

4.Replace screen.

 

 

5.Carburetor requires adjustment.

5.Contact an authorized service dealer.

 

6.Carbon build up.

6.Contact an authorized service dealer.

 

7.Compression low.

7.Contact an authorized service dealer.

Engine

1.Choke partially on.

1.Adjust choke.

smokes

2.Fuel mixture incorrect.

2.Empty fuel tank and refill with

excessively.

 

correct fuel mixture.

3.Air filter dirty.

3.Clean or replace air filter.

 

 

4.Carburetor requires adjustment.

4.Contact an authorized service dealer.

Engine

1.Fuel mixture incorrect.

1.See “Fueling Your Unit.”

runs hot.

2.Spark plug incorrect.

2.Replace with correct spark plug.

 

3.Carburetor requires adjustment.

3.Contact an authorized service dealer.

 

4.Carbon build up.

4.Contact an authorized service dealer.

DECLARATION OF CONFORMITY

EC Declaration of Conformity (Only applies to Europe)

We, Husqvarna AB, SE-561 82 Huskvarna, Sweden, tel: +46--36--146500, as authorised representative in the Community, declare that the garden blower/vacuum model Partner GBV 345 with serial numbers dating from 2009 and onwards (the year is clearly stated on the rating plate, followed by the serial number), comply with the requirements of the COUNCIL’S

DIRECTIVES:

of 17 May 2006 “relating to machinery” 2006/42/EC;

of 15 December 2004 “relating to electromagnetic compatibility” 2004/108/EC, and applicable supplements; and

of 8 May 2000 “relating to the noise emissions in the environment” in accordance with Annex V of 2000/14/EC. For information relating to noise emissions, see Technical data section.

The following standards have been applied: EN ISO 12100-1/A1:2009, EN ISO 12100-2/A1:2009, CISPR 12:2007.

SMP Svensk Maskinprovning AB, Fyrisborgsgatan 3, S--754 50 Uppsala, Sweden, has performed voluntary type examination on behalf of Husqvarna AB. The certificate(s) are numbered: SEC/09/2024.

09--11--01

Ronnie E. Goldman, Director of Engineering Authorized representative for Husqvarna AB and responsible for technical documentation

-- 11 --

Page 11
Image 11
Partner Tech GBV 345 instruction manual Declaration of Conformity, Troubleshooting Table Cause Remedy, Directives