Framer

Framer

The framer is used to determine the status of

 

the line. In normal operation the framer trans-

 

mits and expects to receive framed packets

 

from the far end. If the framer receives framed

 

packets from the far end, CTS and CD will be

 

active. If framed packets are not received, CTS

 

and CD will be inactive. The restart procedure

 

uses this information to determine if a valid con-

 

nection is made (cable disconnect, poor cable

 

quality, etc). In normal Data Mode, if the box

 

receives 4 seconds of unframed packets it will

 

restart the box and begin trying to re-establish a

 

connection with the far end. The distinction

 

between framed packets and unframed packets

 

becomes important when we discuss the Pattern

 

Generator.

Pattern Gen/Det

This part of the Processor generates and

 

detects the 511/511E patterns. When transmit-

 

ting 511 patterns, the information is unframed

 

(because it originates after the framer) and is

 

intended to be evaluated only by another

 

Processor. If the units are in Data Mode and the

 

pattern generator is enabled on one end of the

 

link, the far end will begin receiving unframed

 

packets and assume that the line has gone

 

down. During test modes, we force the pattern

 

generator to time out before it can cause the link

 

to be killed.

Loop Control

This part of the Processor is used to control

 

loop-backs. In a Local Loop, the data is looped

 

back towards the local DTE. In a Remote Loop,

 

the data is looped back to the line, but it is also

 

allowed to pass through to the framer and to the

 

remote DTE.

Restart Procedure The restart procedure is in place to allow the

and Time Outs units to re-establish a connection after the framer begins seeing unframed packets. The Test Model Timing Chart below shows the amount of time the framer must see consecutive unframed packets before the unit will restart and try to establish a new line connection. The rea- son that there are different Restart Times will become apparent after reading the rest of the document. The 511/511E Time Out shown refers to the amount of time the 511/511E pattern will be valid. At the end of this time the pattern will automatically turn itself off and the normal data path will be re-established. The ER led will flash indicating to the user that the test has timed out. The ER led will stop flashing once the 511/511E switch is placed into the normal position.

Test Mode Timing

Item

 

Elapsed Time (seconds)

Start Up

50

Data Mode

4

 

511/511E Generator Enabled

60

(The generator will stop after 45 seconds.)

Remote End of an RDL

60

 

511/511E Time Out

45

(The pattern generator will automatically turn

 

off after 45 seconds. The ER LED will flash until

 

the user turns off the 511/511E switch.)

Symbol Indicators

This symbol designates the origination or the termination of a data path. The direction of the arrow connected distinguish the two data paths.

This symbol designates an invalid data path. If there is data present it should be ignored.