3.1.1 CONFIGURATION SWITCH SET “S1”

The DIP switches on S1 set data rate, clock source, async./sync. mode and carrier control method. The default settings are summarized in the table below. Following the table is a description of all possible S- 1 switch settings.

 

S1 SUMMARY TABLE

 

 

 

Position

Function

Factory Default

S1-1

Data Rate

On

}

 

S1-2

Data Rate

Off

9,600 bps

S1-3

Data Rate

Off

 

S1-4

Data Rate

On

 

S1-5

Clock Source

On

} Internal

S1-6

Clock Source

On

S1-7

Async./Sync.

On

 

Async.

S1-8

Carrier Control

Off

Constantly On

 

 

 

 

 

S1-1 through S1-4: Data Rate Setting

Switches S1-1 through S1-4 are set in combination to determine the asynchronous and synchronous data rate for the Model 1140ARC.

S1-1

S1-2

S1-3

S1-4

Setting

On

On

On

On

1.2 Kbps

Off

On

On

On

1.8 Kbps

On

Off

On

On

2.4 Kbps

Off

Off

On

On

3.6

Kbps

On

On

Off

On

4.8 Kbps

Off

On

Off

On

7.2

Kbps

On

Off

Off

On

9.6

Kbps

Off

Off

Off

On

14.4

Kbps

On

On

On

Off

19.2 Kbps

Off

On

On

Off

28.8

Kbps

On

On

Off

Off

38.4

Kbps

Off

On

Off

Off

57.6

Kbps

S1-5 and S1-6: Clock Source

Switches S1-5 and S1-6 are set in combination to determine the transmit clock source for the Model 1140ARC.

S1-5

S1-6

Setting

On

On

Internal transmit clock

Off

On

Receive recover clock

On

Off

External transmit clock

S1-7: Asynchronous/Synchronous Mode

The setting for switch S1-7 determines whether the Model 1140ARC is in asynchronous or synchronous operating mode.

S1-7

Setting

On

Asynchronous

Off

Synchronous

S1-8: Carrier Control Method

The setting for switch S1-8 determines whether the carrier is

“constantly on” orcontrolled“ by RTS”. This setting allows for operation in switched carrier, multipoint and/or hardware handshaking applications.

S1-8

Setting

Off

Constantly On

On

Switched Carrier

5

6

Page 4
Image 4