4.0 INSTALLATION

Once the Model 1184 or 1185 is properly configured, it is ready to connect to the fiber interface, to the serial port, and to the power source. This section tells you how to make these connections.

4.1 CONNECTION TO THE FIBER INTERFACE

The Model 1184 supports communication between two terminal equipment at distances to 3 miles (4.8km) and data rates to 128 kbps (sync) or 19.4 kbps (async). Model 1185 also supports distances up to 3 miles (4.8km), but at rates up to 256 kbps (sync) or 38.4 (async). Figure 3 shows the position of the interface connectors on the Model 1184 or 1185 back panel.

1 On

Quik-Connect

Interface Module

Fiber

0 Off

Interface Port

Figure 3. Rear Panel of Model 1184/1185, Showing Interface and Power Connectors

These short range modems are designed to work in pairs. You will need one at each end of single 50 or 62.5 micron multi-mode fiber cable. The fiber cable connects to each Model 1184 or 1185 using either an ST or an SMA connector. Figure 4 below shows a close-up of both connector types.

SMA

ST

Figure 4. Close-up of ST and SMA Connectors

4.2 CONNECTION TO THE SERIAL PORT

The serial port interface on the Model 1184 and 1185 uses interchangeable QuickConnect™ Modules. Each QuickConnect™ Module has a 50-pin card edge connector on one side and a serial port interface on the other. Figure 2 below shows how a QuickConnect™ Module plugs into the back of the Model 1184/1185.

Line

Port

Interface

1

ON

 

0

OFF

 

Figure 5. Installation of Model 1184/1185 Plug-in Serial Interface Module

4.2.1 Changing QuickConnect™ Modules

When you purchase a particular version of the Model 1184 or 1185, it should be shipped to you with the appropriate QuickConnect™ Module already installed. If you need to install a different QuickConnect™ Module, follow these steps:

Removing the Existing QuickConnect™ Module

1)Turn the power switch off. Leave the power cord plugged into a grounded outlet to keep the unit grounded.

2)Loosen the two thumbscrews on the module by turning them counterclockwise.

3)Grasp the two thumbscrews and gently pull the module from the unit. Apply equal force to the thumbscrews to keep the module straight during the removal process.

9

10

Page 6
Image 6
Patton electronic 1184, 1185 user manual Installation, Connection to the Fiber Interface, Connection to the Serial Port

1184, 1185 specifications

The Patton Electronics 1185 and 1184 models are part of a trusted series of network devices designed to facilitate communication and enhance network performance in various applications. These products are widely recognized for their robust features, user-friendly interface, and reliable performance.

The Patton 1185 is primarily a multi-port serial device server that enables the connection of multiple serial devices to an Ethernet network. This model can support up to eight serial ports, offering a straightforward solution for integrating legacy serial devices like POS terminals, industrial equipment, and IoT devices into modern network infrastructures. The 1185 is equipped with standard RS-232, RS-422, or RS-485 interfaces, allowing flexibility in terms of device compatibility. Its ability to convert serial data to TCP/IP makes it ideal for remote monitoring and management applications.

On the other hand, the Patton 1184 serves as a single-port serial device server. Like its counterpart, it provides the functionality to connect serial devices to Ethernet networks. The 1184’s compact design and ease of installation make it suitable for small-scale installations where space is a premium. It supports a variety of serial interfaces, including RS-232, enhancing compatibility with various devices.

Both models feature patented Auto-Sense technology, which automatically adjusts serial port settings to match connected devices, easing the configuration process and reducing setup time. They are equipped with a web-based management interface that allows for simplified configuration, monitoring, and troubleshooting through any web browser.

In terms of reliability, the Patton 1185 and 1184 boast a wide operating temperature range, making them suitable for use in harsh environmental conditions. They also feature surge protection and failover capabilities to ensure consistent data transmission and minimal downtime. Moreover, both models incorporate support for standard networking protocols, including TCP/IP, UDP, and DHCP, facilitating seamless integration into existing networks.

With a commitment to quality and performance, Patton Electronics has designed these models to meet the demands of various sectors, including retail, telecommunications, and industrial automation. The Patton 1185 and 1184 represent innovative solutions that combine functionality, ease of use, and robust construction, making them a preferred choice for businesses looking to modernize their communications infrastructure.