Configure DIP switch S2
Switches S2-1 through S2-8 are for configuring Local/Remote Loop, RDL response, and front panel switch operation (see Table 2). Descriptions of the switch options follow the table.
Table 2: Switch S2 summary
Position | Function | Default Setting | Selected Option |
| | | |
S2-1 | Local/Remote Loop | OFF | Local Loop |
| | | |
S2-2 | | | |
S2-3 | | | |
| Reserved | | |
S2-4 | | |
| | | |
S2-5 | | | |
| | | |
S2-6 | | | |
| | | |
S2-7 | Response to RDL | OFF | Enabled |
| | | |
S2-8 | Front panel switches | OFF | Enabled |
| | | |
Switch S2-1: Local/Remote Loop. Switch S2-1 determines which Loop can be activated from the front panel loop switches (P1 to P4)
S2-1 | Loop selected |
| |
OFF | Local Loop |
ON | Remote Loop |
| |
Switch S2-7: Response to RDL. Switch S2-7 enables or disables the ability of the model 1194 to respond to RDL (Fiber Loop)
S2-7 | RDL Response |
| |
ON | Disabled (no response) |
OFF | Enabled |
| |
Switch S2-8: Front Panel Switches. Switch S2-8 enables or disables front panel switches, affecting the operation of P1 to P4 (loop switches) and test pattern switches. In the ON position, S2-8 disables the operation of front panel switches preventing the accidental activation of diagnostic loops and test patterns.
S2-8 Front panel Switches
ONDisabled
OFFEnabled