3.0 INSTALLATION
Because the CopperLink Ethernet Extender requires no configuration, it can be installed quickly.
Note If asymmetric transmission or line rates other than 12.5 Mbps are required , refer to section 4.0, “Configuration” on page 16.
3.1 UNIT INSTALLATION
Do the following:
1.Make a ground connection for the unit (refer to section 3.2, “Ground- ing the CopperLink Ethernet Extender” on page 10).
2.Connect the line interface between the units (refer to section 3.3, “Connecting the
Note See Figure 2 for the unit’s rear panel arrangements.
3.Connect the Ethernet interface (refer to section 3.4, “Connecting the
4.Connect the power plug (refer to section 3.5, “Connecting Power” on page 15).
CopperLink 2168A/TB45
|
| Power |
CopperLink 2168A |
| connector |
CopperLink 2158A |
| Ethernet |
|
| |
|
| port |
|
| CopperLink |
|
| terminal block |
| Ground | interface |
|
| |
| stud | CopperLink |
|
| |
|
| |
| Power |
|
| connector |
|
Ethernet
port
Ground
stud CopperLink
Figure 2. CopperLink Ethernet Extender rear panel
9