The Main Menu options are briefly described below.
aSystem Configuration options allow you to change various aspects of the Model 2701RC operation, e.g., framing, line coding, and aggregate bandwidth.
bSystem Diagnostics/Statistics options allow you to monitor the network performance, initiate V.54 loops, local loops, and send test patterns. Network performance parameters are updated once a second, giving you the ability to quickly deter- mine if there is a problem.
cUnit Options allow you to customize the Model 2701RC for your location. You can change the default header names to give each unit a unique name and password. Also, you can reset the unit to its default settings without the manual. It also has a Service Information screen in case you need technical assistance from Patton.
dSave Changes Once you have configured the unit to your satisfaction, you can save the changes permanently by exe- cuting the Save Changes command. This will update the unit’s configuration and save all the parameters to permanent mem- ory.
eLogoff For security, log off the control menu by executing the Logoff command. This will blank the screen until an [Enter] key is pressed.
3.3.4 System Configuration
The System Configuration menu looks like this:
The System Configuration options are described below:
aLine Format: G.703 (default)
Options: G.703, G.704
G.703: G.703 is unframed, 2.048Mb/s. In this case, the DTE rate is equal to the line rate at the network interface (NI). CAS MF and
G.704: G.704 reserves TS0 for signaling and frame alignment. Maximum data rate depends on whether CAS MF is enabled or not.
21 | 22 |