Patton electronic 2707/I user manual E1 Link

Models: 2707/I

1 24
Download 24 pages 5.42 Kb
Page 18
Image 18

 

Table 2: LED descriptions

 

 

LED

Description

 

 

E1 Link

(Active Green) Solid green (On) indicates that the end to

 

end E1 Link is up, signifying that the link is active. The E1

 

Link LED is Off when the link is down.

 

 

10BT Link

(Active Green) Solid green indicates that the 10Base-T

 

Ethernet interface has detected a valid SQE heartbeat,

 

signifying a valid 10Base-T connection.

 

 

Status

Blinks yellow from one to eleven times to indicate system

 

status. Each pulse pattern is separated by a 2 second

 

“off” period. Greater pulse patterns have higher priority

 

(buffer saturation has greater priority than an empty MAC

 

table). Valid system statuses are:

 

1 pulse—system status is okay

 

2 pulses —no MAC entries in the MAC Address Table

 

3 pulses—Clear to Send (CTS) or Carrier Detect (DCD)

 

from base unit are not asserted

 

4 pulses—IM1/I buffer is saturated

 

5 pulses —WAN receive frame(s) too large

 

6 pulses —WAN receive frame(s) not octet aligned

 

7 pulses—WAN receive frame(s) aborted

 

8 pulses—Detected WAN receive frame(s) with CRC

 

9 pulses—Detected LAN receive frame(s) too large

 

10 pulses—Detected LAN receive frame(s) not octet

 

aligned

 

11 pulses—Detected LAN receive frame(s) with bad

 

CRC

 

 

TM

(Active Yellow) Solid Yellow indicates an Active Test

 

Mode.

 

 

18

Page 18
Image 18
Patton electronic 2707/I user manual E1 Link